Last seen: Feb 19, 2025
@morh It seems odd that F1 and F2 are used for the HVACs, but F3 and F4 are used for the ASHPs, but thanks for confirming this. I will give it a go.
Go to Settings - Options - User Mode - Wired Remote Controller - Current Time
@elgreco69 @morh Can you help me with the wiring please? The descriptions that I have seen are for Samsung HVACs rather than heat pumps, so I just ...
One thing that I would like to know is whether Homely can control the way that LWT changes when the heat pump starts up. Does it just tell the ASHP th...
@bontwoody Thanks very much for pointing this out as I was unaware that you could do this. The need for a hot water cylinder is the one thing I feel i...
@bauchie I like the iboost. It’s pretty simple and it does our hot water for 7-8 months of the year. It operates independently of the heat pump and is...
tech.aircon@samsung.com may be able to help. My immersion heater is connected only to the solar iboost, so cannot help you much. Prior to the iboost b...
@ecobaker Are you using the thermostat in the Samsung wired remote controller? If so, the best way to get your weather compensation settings right wou...
I have this pump and it has 3 settings which approximate to 6, 7 or 8 metres of head assuming I have correctly understood the pump curves on the Grund...
The display on your remote wired controller indicates that you are using an external thermostat and so the room temperature displayed will have no eff...
@jamespa Thank you for your very helpful insights. I have been looking afresh at the important effect of oversizing of a heat pump. On the face of ...
@jamespa I do apologise for a really crass error. You are absolutely right that 24kWh of energy produced at a COP of 4 would require 6 kWh of consumpt...
- 21 Forums
- 1,962 Topics
- 42.6 K Posts
- 47 Online
- 2,275 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
It's INSANE how wrong they have the sizing (and even sh...
By BAMi , 14 minutes ago
-
RE: Towel rails. An unexpected final hurdle. Resolved
@jamespa Solved thanks to your help. I found a ladder t...
By Davesoa , 14 minutes ago
-
RE: Heat Pump Sizing & Installation Costs
Perhaps useful to have installed date too? To get conte...
By Tim441 , 1 hour ago
-
RE: What is the best strategy for operating a very oversized heat pump?
Something else... that works for some people... LG ha...
By Tim441 , 1 hour ago
-
RE: Setback savings - fact or fiction?
@cathoderay I see you are continuing to misquote from t...
By SUNandAIR , 3 hours ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
So I turned my thermostats down last night And w...
By Joshua , 3 hours ago
-
RE: SolarPV tables / online calculator
I'd be interested what others find whilst using that we...
By Majordennisbloodnok , 3 hours ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
The debate over buffer tanks in heat pump systems has b...
By Mars , 4 hours ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 15 hours ago
-
RE: Act now to defer the UK road tax increase on EVs
@majordennisbloodnok Damn right sir. my attempt at iron...
By Jancold , 18 hours ago
-
RE: ASHP and heating issues in new build house
That’s good gives you more capacity. It made me think, ...
By Terry1812 , 20 hours ago
-
RE: Seewet manhole cover within r290 exclusion zone
Thanks! I asked Vaillant, and they say I should be fi...
By dbrb2 , 22 hours ago
-
Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
I'm running my Aerona 3 on WC and the 'warm end of that...
By damonc , 23 hours ago
-
RE: Do I just go with the lowest quote for my heat pump?
So after signing in Sept in two weeks the install may s...
By Jancold , 1 day ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
When you are renovating is always a good time, as it ma...
By JamesPa , 1 day ago
-
RE: Just one room not reaching desired temperature
Looks like this issue is now resolved. Aira installed a...
By ChandyKris , 1 day ago
-
There have been several people on the OpenEnergyMonitor...
By RobS , 2 days ago
-
RE: Say hello and introduce yourself
Good point @jamespa But that probably strengthens @ch...
By Transparent , 2 days ago
-
RE: Visit a Heat Pump sessions.
Congratulations @toodles, that's a fantastic result. We...
By Old_Scientist , 2 days ago
Latest Topics
-
Heat Pump Sizing & Installation Costs
By Mars 4 hours ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
By Mars 4 hours ago
-
SolarPV tables / online calculator
By MichelleC 11 hours ago
-
Samsung Gen 7 R290 12kW is not behaving how I expected
By Joshua 23 hours ago
-
By Toodles 2 days ago