Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Mike H
@mike-h
Member
Reputable Member
Joined: Dec 1, 2021
Last seen: Dec 10, 2025
Topics: 5 / Replies: 195
Reply
RE: Replacing knackered oil boiler with Samsung ASHP - Perthshire

The Water Outlet temp on the controller screen will display the current flow temperature whether in space heating mode or during DHW heating, so durin...

6 months ago
Reply
RE: Replacing knackered oil boiler with Samsung ASHP - Perthshire

The Legionella disinfection is done by the immersion heater, so normally it would not be responsible for the high flow temperature. When the heat pump...

6 months ago
Reply
RE: Samsung Heat pump with Yonos Pico circulating pump running all the time

@old_scientist I realise that the pump running 24/7 is now thought to be due to incorrect wiring and not the FSV settings. I just wanted to check that...

7 months ago
Reply
RE: Samsung ASHP scheduling help

You may have a different model from me - mine is a Gen 6 12kW Samsung - but on mine there is no feedback from the controller on LWT when room temperat...

1 year ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

Running continuously will usually produce the best COP, but having setbacks where the pump is off for periods allowing the house to cool eg overnight ...

1 year ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

That seems odd and I have not seen or heard of that before. According to Midsummer Wholesale the Samsung controller is supposed to be a bit cleverer t...

1 year ago
Reply
RE: How much radiator capacity do I need for an air source heat pump?

HTC stands for Heat Transfer Coefficient - heat loss per C degree difference between IAT and OAT. It’s advantage is that it is independent of design t...

1 year ago
Reply
RE: How much radiator capacity do I need for an air source heat pump?

Delta T 20 implies that your desired room temperature would be 17.5C as the mean radiator temperature would be 37.5C at a flow temperature of 40C and ...

1 year ago
Reply
RE: New 5kW Samsung Gen6 heat pump owner with loads of questions

If you set it at 19C it will switch off at 19.9/20C and stay off until it drops to 18.9C. The 1C hysteresis cannot be changed. The alternative is to u...

1 year ago
Reply
RE: New Samsung 12KW Heat Pump Help

@bontwoody Sorry for the lack of explanation. I was taking my comment from Glyn Hudson's recent observation on the OEM forum - "I found the onboard Sa...

1 year ago
Reply
RE: New Samsung 12KW Heat Pump Help

@bontwoody I think the fact that your Samsung displays generated energy as less than OEM generated energy whereas mine is the reverse may just demonst...

1 year ago
Reply
RE: New Samsung 12KW Heat Pump Help

@bontwoody That doesn't tally with my Samsung I'm afraid. For today, Samsung display's Generation/Usage = 3.05 compared to my Class 1 Electricity and ...