Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 10, 2025
The Water Outlet temp on the controller screen will display the current flow temperature whether in space heating mode or during DHW heating, so durin...
The Legionella disinfection is done by the immersion heater, so normally it would not be responsible for the high flow temperature. When the heat pump...
@old_scientist I realise that the pump running 24/7 is now thought to be due to incorrect wiring and not the FSV settings. I just wanted to check that...
You may have a different model from me - mine is a Gen 6 12kW Samsung - but on mine there is no feedback from the controller on LWT when room temperat...
Running continuously will usually produce the best COP, but having setbacks where the pump is off for periods allowing the house to cool eg overnight ...
That seems odd and I have not seen or heard of that before. According to Midsummer Wholesale the Samsung controller is supposed to be a bit cleverer t...
HTC stands for Heat Transfer Coefficient - heat loss per C degree difference between IAT and OAT. It’s advantage is that it is independent of design t...
Delta T 20 implies that your desired room temperature would be 17.5C as the mean radiator temperature would be 37.5C at a flow temperature of 40C and ...
If you set it at 19C it will switch off at 19.9/20C and stay off until it drops to 18.9C. The 1C hysteresis cannot be changed. The alternative is to u...
@bontwoody Sorry for the lack of explanation. I was taking my comment from Glyn Hudson's recent observation on the OEM forum - "I found the onboard Sa...
@bontwoody I think the fact that your Samsung displays generated energy as less than OEM generated energy whereas mine is the reverse may just demonst...
@bontwoody That doesn't tally with my Samsung I'm afraid. For today, Samsung display's Generation/Usage = 3.05 compared to my Class 1 Electricity and ...
- 27 Forums
- 2,733 Topics
- 64.2 K Posts
- 1,525 Online
- 7,138 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Questions about A2A for heating as well as cooling
If @ashp-bobba is around, he may be able to give you mo...
By Mars , 9 hours ago
-
RE: Aircon - in listed buildings
@etchedpixels thanks for giving such a full and helpful...
By GrahamF , 13 hours ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
Another idea if the above don't work - there are compan...
By downfield , 15 hours ago
-
RE: Love veg, hate watering cans
They have their downsides but boreholes are great in th...
By ian33a , 16 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist The service engineer powered down the ex...
By Papahuhu , 17 hours ago
-
RE: Issue with Samsung Cascade System
@jamespa It's a funny system, but was out only option l...
By Renewables345 , 21 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Thanks, I like the chart, very helpful and this will de...
By baroquebank , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Production resumed to normal once the issue ...
By MK4 , 2 days ago
-
RE: Digest of UK Energy Statistics
That sounds painful. It would be much better to charg...
By Transparent , 2 days ago
-
Hole diameter is small but hole length is also very sma...
By bobflux , 2 days ago
-
RE: Are Wind Turbines Really “Losers”?
We were sailing near a wind farm in the North Sea last ...
By Jeff , 2 days ago
-
@trebor12345 The idea is to ensure that Powerwall knows...
By Toodles , 3 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
'hard limited' could be in 'admin' password protected s...
By JamesPa , 3 days ago