Activity
 
Notifications
Clear all
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Nov 27, 2025
Topics: 19 / Replies: 3526
Reply
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira

I agree with all of that. 220 pages is perhaps 210-215 pages too much. Unfortunately there is no substitute for (a) understanding some basics (which...

6 days ago
Reply
RE: Don’t Install a Heat Pump Until You Read This

@davidnolan22 Perhaps you could post some more info about your setup, house and system and WC parameters - you never know it may be possible to diag...

6 days ago
Reply
RE: Help me keep the faith with my air source heat pump installation

OK. I have 2.8 for DHW and 3.4 for space heating running at an actual FT of about 36. Yours does seem a bit low depending on what FT you were runnin...

6 days ago
Reply
RE: 10kw heat pump run in 24*7 data?

Don't forget to increase max ft also. Mine is set to 55, way clear of the curve. I think that might even have been the default.

7 days ago
Reply
RE: 10kw heat pump run in 24*7 data?

Suggest, as a test, you turn up the WC curve a lot so any change or not is unambiguous. I'd also set max ft to say 55 to get this parameter out of th...

7 days ago
Reply
RE: 10kw heat pump run in 24*7 data?

Emptying the NR schedule will turn off NR mode yes. Im not sure you have a reason to do so yet though.   With such a small reduction in O...

7 days ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

Not surprised by that. FWIW my Vaillant has done more or less exactly the same. Its COLD out there! With those figures I get an overall SCOP of 4, ...

7 days ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Fair enough (the raging). Try not to let it upset you (easier said than done I know). Unlike some less fortunate people you remain in control it seem...

7 days ago
Reply
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira

I think that's what they do, so they are varying ft. It would be good to see some plots at various oat values  

7 days ago
Reply
RE: Help me keep the faith with my air source heat pump installation

No cycling there except possibly at midnight on the first day. You would expect so but don't forget cop varies with oat also. Also depends on how l...

7 days ago
Reply
RE: Help me keep the faith with my air source heat pump installation

Possibly. I haven't yet worked out what Vaillant do with water pump speed as I can't monitor it and don't have a reason to care. Why is it a 'proble...

7 days ago
Reply
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira

So is the flow temp changing as well or is that fixed?

7 days ago