Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 4, 2026
Because not everyone needs it and to be effective it would need to be not joined too much and not trap air, both to avoid heat transmission by conduct...
You should (almost) always reject having a buffer, by which I mean any kind of tank between the heat pump and emitters that is connected both to feed ...
No, but the heat pump must be capable of delivering a SCOP of at least 2.8, which for most means max 55C. You are well within that by the sound of it...
TBH I dont understand how that works. Ultimately all the radiators are connected back to the same pipe; I dont understand personally how turning some ...
Sorry to hear about the problems, its going to be something fixable for sure. No (I have only one zone) but the obvious questions are ...
No. The regulations are here Regulation 9(2) b is the key one As your robustly assessed heat loss is about 6kW, with the right instal...
You can selectively shut down radiators to test flow rates in individual lines or groups of lines. Obviously you wont expect to get the full flow rat...
I have seen it stated that the declared calorific value does not include latent heat of condensation (which is very plausible) and therefore that, in ...
Yes. Vaillant for example has a wireless oat sensor (not sure if there is also a wired version) which can be suitably located. I would imagine that ...
Mine certainly does. My oat sensor is tucked under the eves of a north facing garage which ensures sun never gets to it.
Mine certainly does. My oat sensor is tucked under the eves of a north facing garage which ensures sun never gets to it.
North facing wall out of direct sunlight atcall times of day and yes not exposed to next doors flue. I suppose you could put it in a Steven...
- 27 Forums
- 2,783 Topics
- 65.6 K Posts
- 3,424 Online
- 7,187 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
I've got a podcast recording scheduled this week where ...
By Mars , 6 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
I’m a little late posting this, but it’s genuinely one ...
By Mars , 7 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
Ah, that makes sense when a combi is in place. The boil...
By Batpred , 9 hours ago
-
RE: Replacing Storage Heaters with a Heat Pump in a Stone Cottage
@bobflux Thanks, that gives me something to check the i...
By Paul1098 , 10 hours ago
-
RE: DIY Heat Pump Installations: Navigating Legal and Regulatory Hurdles
Without doing some research I can't immediately answer ...
By JamesPa , 11 hours ago
-
RE: Tesla Powerwall (2) Calibration Cycles
For Powerwall calibration, avoid forcing repeated deep ...
By EnergyStorageTech , 18 hours ago
-
Over the years, due to the non barrier PEX underfloor h...
By bobflux , 1 day ago
-
RE: Getting closer to a finished Haier system
All the 45° elbows required for getting the primaries i...
By Singlespeed , 1 day ago
-
RE: battery storage without solar
Indeed, current on the grid input = current used for ch...
By bobflux , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu @papahuhu A lot of tears and sweat went into ...
By Andris , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
We have the same problem, 12 mature trees clip the morn...
By Papahuhu , 3 days ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
I had a battery and inverter installed a while ago, my ...
By Batpred , 4 days ago
-
RE: Is This Initial Free Quote From Octopus Trusted Partner Reasonable?
@ltron2 The EPC on our house is A-92, however that i...
By Rob of York , 4 days ago
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
The layout is confusing - much better like this: We b...
By downfield , 5 days ago
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
My experience, backed up by opinions from various frien...
By Majordennisbloodnok , 5 days ago