Reply
RE: why solar diverters for HW instead of the heat pump?

I should probably add to my comments above that, whilst I can definitely see an argument for using a solar diverter in some cases - most particularly ...

2 hours ago
Reply
RE: why solar diverters for HW instead of the heat pump?

The argument I can think of is that solar diverters precisely match the power draw to the available excess solar power, which heat pumps cannot do. T...

3 hours ago
Reply
RE: Commencing on an ASHP Installation Process

Lots of reading and questioning which the background makes easier. I started when I first thought about getting a heat pump for myself and it became ...

7 hours ago
Reply
RE: Commencing on an ASHP Installation Process

Crudely dividing by somewhere between 2000 and 2900 gives an estimate dependant on assumptions/who you believe. My total gas consumption for a 7kW ho...

12 hours ago
Reply
RE: Commencing on an ASHP Installation Process

11kW does sound way over in that case! As you say it will be interesting to see what others come up with, maybe try to get a copy of the calculations...

1 day ago
Reply
RE: Commencing on an ASHP Installation Process

Is 116 sqm both floors, or just the footprint? If the former then 11kW sounds possibly a bit high to me. Your conservatory may be dominating however...

2 days ago
Reply
RE: Commencing on an ASHP Installation Process

Hi I have just posted the below in response to your intro text. ------------- In terms of getting quotes, be prepared to get a fair few to find ...

2 days ago
Reply
RE: Say hello and introduce yourself

Welcome to the forum. If you are new to ASHPs I suggest you read the introduction here. @editor also publishes a couple of books guiding you thro...

2 days ago
Reply
RE: Help me keep the faith with my air source heat pump installation

I agree with @mars. My install was not dissimilar. I got a 7kW Vaillant, 200l cylinder and 4 rads (including one fancoil) for 12.5K les grant. Im...

3 days ago
Reply
RE: Air Source Heat Pump - Side Alley Suitability

Thats probably fair enough. The degree-days calculation (on which quite a few heating formula are based) uses the formula sum (max (Tbase-OAT ,0)) ...

3 days ago
Reply
RE: Air Source Heat Pump - Side Alley Suitability

Thats a slightly awkward number because, by the time you add an allowance for heating DHW, it will push you towards a 10kW machine rather than 7-8, wh...

3 days ago
Reply
RE: Air Source Heat Pump - Side Alley Suitability

All sounds sensible to me and to be clear, the idea of swapping to a ASHP at the same time as fixing the distribution is sound IMHO, if you are going ...

3 days ago
Page 1 / 197
Share:

Join Us!

Trusted Installers

Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.

✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available

👉 Find your installer now!

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security