Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Famed Member
Joined: Jan 20, 2022
Last seen: May 6, 2026
Topics: 16 / Replies: 3158
Reply
RE: Running from backup generaor in powercut?

Us Moderators have had a (private) discussion in 2025 about peak current demand from heat-pumps. It certainly used to be the case that there was hig...

4 months ago
Reply
RE: Exploring the role of alternative clean heating solutions - Government Consultation

Yes, I agree that the dearth of public knowledge of energy issues is a major reason why there is so little engagement with future energy strategy........

4 months ago
Reply
RE: Exploring the role of alternative clean heating solutions - Government Consultation

There's more to gain by submitting a personal response.It's extremely rare for individuals to respond to Government consultations. It looks like thi...

4 months ago
Reply
RE: Running from backup generaor in powercut?

Interesting question. The usual assumption is that generation sources based on mechanical rotation will naturally provide genuine sine-wave output. ...

4 months ago
Reply
RE: Is it normal to use power from the grid when running off the battery?

The Eastron SDM630 range is known to me.I have one here, but it's still in the box awaiting a monitoring trial which has yet to start. Your meter wi...

4 months ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

Or alternatively, forget the need to get entrenched with compatibility lists,and instead get acquainted with the Open Modbus Standards and certificati...

4 months ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

Well that's of great interest. I'll tell you here of my interest, but don't let's expand on this discussion in this topic please.It's an enormous su...

4 months ago
Reply
RE: Is it normal to use power from the grid when running off the battery?

Well I'm pleased I suggested checking the CT connections, but wasn't aware that there's a meter also involved. I'd be interested to understand this ...

4 months ago
Reply
RE: Solis inverters S6-EH1P: pros and cons and battery options

A domestic 3ph Smart Meter operates in Vector Sum Mode. If a home with a single-phase solar inverter exports on one phase and imports on the other t...

4 months ago
Reply
RE: Is it normal to use power from the grid when running off the battery?

@johnnyb - check the connections for your Current Transformer at the inverter. Re-do them if in doubt and see if this makes a change. Also ch...

4 months ago
Reply
RE: Reliable, easy to use home battery options

Correct. LiFePO₄ cells mustn't be charged if their temperature is 0°C or below.That would cause permanent damage to the Lithium electrode plates. ...

4 months ago
Reply
RE: Water outage in the the south-east

Indeed!Any contamination in the well water would be transferred into the water main, making your neighbours 'unwell'. So don't do that.   A...

4 months ago
Forum
Page 23 / 265
Share:

Join Us!

Latest Posts

Members Online

Click to access the login or register cheese
x  Powerful Protection for WordPress, from Shield Security PRO
This Site Is Protected By
Shield Security PRO