Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Transparent
Transparent
@transparent
Moderator
Famed Member
Joined: Jan 20, 2022
Last seen: May 5, 2026
Topics: 16 / Replies: 3157
Reply
RE: What determines the SOC of a battery?

The conclusion I'm coming to is that it's presumptuous of an inverter to think it can display SoC with sufficient accuracy,and that it shouldn't be re...

3 months ago
Reply
RE: Safety update; RCBOs supplying inverters or storage batteries

See matching discussion here in the topic about Plug'n'Play Balcony Solar kits.

3 months ago
Reply
RE: What determines the SOC of a battery?

The answer to this problem is easy if the LiFePOâ‚„ are 'at rest' with no current passing in either direction. Under those conditions there will be an...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

We're talking about the direction from which the power could potentially flow. The RCBO has two sources of electrical energy applied to it – the gri...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

The issue I was referring to in that geographical area was for fixed solar-inverters, not plug-in kits. I've just checked online (using my rudimenta...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

In response to @jamespa 's similar point, there is an unfortunate history of generation devices (inverters) continuing to output power after the time-...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

It's the other way around @batpred Newer RCDs and RCBOs are most likely to have a small solenoid with the coil being energised via a control circui...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

Allow me to me turn the argument around. Let's suppose it was the MCS proposing that "the solenoid coil in the RCBO won't burn out because the micro...

3 months ago
Reply
RE: Advice Needed For New Ground Source Heat Pump System in SW Scotland

I recommend talking with Kensa Heat Pumps who are a UK GSHP manufacturer. They're nowhere near you geographically, but actually based almost as far ...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

I respectively disagree @robl Here's the relevant paragraphs from the BEAMA Report which alerted the IET to the problem back in 2024   Th...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

It's only in the past couple of years that bi-directional RCBOs have been available...... and only a year since it became illegal to fit a standard (u...

3 months ago
Reply
RE: Plug and play solar. Thoughts?

I don't think that is possible, which is why I described the problem in my post. The Plug'n'Play inverter could operate ok if plugged into a circuit...

3 months ago