Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

MK4
MK4
@mk4
Member
Trusted Member
Joined: Jan 27, 2026
Last seen: Apr 9, 2026
Topics: 0 / Replies: 69
Reply
RE: My misgivings about installing ASHP and solar panels via the ECO4 scheme...

@notanexpert What did you end up doing if I may ask? What is your current status?

1 month ago
Reply
RE: Other than heat loss, radiator sizing, ASHP sizing, what else goes into a design and how important is it?

@petch Same with me, I had to insist and taking a leap of faith, undertake the responsibility for not installing a buffer (though I would not even ...

1 month ago
Reply
RE: Tell us about your Solar (PV) setup

Since you seem to quite thoroughly investigate every step you take, how did you choose these levels? I am trying to understand what are the optimal le...

1 month ago
Reply
RE: Peak Energy Products V therm 16kW unit heat pump not reaching flow temperature

@davec @johnd Guys, I have been reading your fascinatingly horrid stories and I am rooting for you! Related to the above, a question also add...

1 month ago
Reply
RE: Tell us about your Solar (PV) setup

Here is an example of local Leroy offerings (in exotic greek...)   Thank you! I did look through them and I got dizzy by the technical l...

1 month ago
Reply
RE: Tell us about your Solar (PV) setup

@bobflux Prey what are the SOC% limits you have set for your battery?

1 month ago
Reply
RE: Tell us about your Solar (PV) setup

I don’t know about IKEA but for sure some DIY chains (like Leroy Merlin) do. A plug and play set of panels that you plug in one socket. One of the r...

1 month ago
Reply
RE: Midea R32 Monobloc MHC-V12W in 1989 Detached House: Noise from Pipes/Airing Cupboard, DHW Schedule Not Always Heating – Advice Needed?

I believe we can attribute this mystery to bad english. Based on how other circulation pumps operate and on the documentation below, I think your Gr...

1 month ago
Reply
RE: Midea R32 Monobloc MHC-V12W in 1989 Detached House: Noise from Pipes/Airing Cupboard, DHW Schedule Not Always Heating – Advice Needed?

I think it means it runs at the same constant speed all the time. From the link below you can download the installation and operation manual, see page...

1 month ago
Reply
RE: Midea R32 Monobloc MHC-V12W in 1989 Detached House: Noise from Pipes/Airing Cupboard, DHW Schedule Not Always Heating – Advice Needed?

@cathoderay Apologies, I meant your secondary circuit. What drives water flow modulation in your secondary circuit.

1 month ago
Reply
RE: Solar Power Output – Let’s Compare Generation Figures

If your inverter can support two strings, perhaps you could have all the shaded panels in one string and the ones that are never shaded in another. We...

1 month ago
Reply
RE: Midea R32 Monobloc MHC-V12W in 1989 Detached House: Noise from Pipes/Airing Cupboard, DHW Schedule Not Always Heating – Advice Needed?

Could it perhaps be because you change set LWT via the adapt script and not via the controller? Perhaps the controller never receives a “return” signa...

1 month ago