Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 15, 2026
@transparent Having seen what you wrote I had a look at my 1 year old CU. It has the surge protector away from the main switch and has an MCB "protect...
Sorry should have said the BMS is not Seplos but Pace with JK balancer.
After much faffing about I got these charts from my setup from the solis. I'm not sure if they are any help? But as for charge parameters I don't know...
Which is why ,I assume,Fogstar fit the JK balancer to their 16Kw Pace BMS batteries?
@batpred So that's it then? Its all wrapped up for future readers! No more discussion needed? I'll toddle off. 😀
@bash Thanks, yes Mine have the JK balancer, they are the ones with the Pace BMS and heating as they are in an unheated conservatory.
@upnorthandpersonal Thanks, for my 12v boat system I have been able to set suitable voltages as the chargers are configurable ( the first battery syst...
I know there are a number of charging periods but had not thought of using them that way. My assumption was that the inverter had automatic charge pha...
I have been trying to get my head around what this all means for the battery life? Like others I want to get the best out of my system (Solis 8Kw and ...
@cathoderay I have had a lipo4 set up on my boat with a shunt on the negative for some years. It is all Victron, it has to be as the BMS is external t...
I have Solis 8Kw inverter and 2 * 16Kwh Fogstar batteries. No solar as yet. I have been on Intelligent Octopus Go since January this year and though a...
Forum Handel @jancold Manufacturer: Daikin Model: EDLA06E2V3 Type: ASHP Arrangement: Monobloc Region: SWest coastal Home type: Semi detach...
- 27 Forums
- 2,746 Topics
- 64.6 K Posts
- 166 Online
- 7,151 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The good, the bad and the not that great – my heat pump installation
So sorry to hear that. If there is anything more we ca...
By JamesPa , 34 minutes ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@jamespa I have been looking at battery prices for my s...
By Ian S , 2 hours ago
-
At the risk of going on: A slight side issue for a foru...
By Bart , 5 hours ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 6 hours ago
-
RE: Mitsubishi Ecodan FTC6 settings
The Mitsi remote thermostat should not be plugged into ...
By F1p , 21 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@lizzie Thank you, very interesting and useful informat...
By Toodles , 1 day ago
-
RE: PV and battery long payback - sense check query
@jamespa I was just commenting on the speed, not sug...
By Batpred , 1 day ago
-
Readers here please note that Derril Water and many oth...
By Transparent , 1 day ago
-
RE: Advice on Vaillant Sensocomfort
Oops, I meant Sensocomfort (the UI to the controls)
By Batpred , 1 day ago
-
RE: Heat Pump Training vs. Real-World Installation
Our instal was very much the opposite. White haired blo...
By Batpred , 1 day ago
-
RE: Flushing system, cleaning and inhibitor
While skim reading a manual for our Vaillant HW tank, I...
By Batpred , 1 day ago
-
RE: 'Chinese Diesel Heater' to heat the home .....
Old thread but I'm new to the forum so new to me. How...
By BlizzardGreen , 2 days ago
-
I'm not sure why you would want to make it more difficu...
By JamesPa , 2 days ago