Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Nov 10, 2026
Topics: 28 / Replies: 5585
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

Ok. When you say max 50 what changes it? Does it in practice run at 50 and if so does the zone valve switch it on and off? Basically I'm trying to...

2 years ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

@rhh2348 have you got graphs to illustrate this, if so can you post them please (or were you sitting and watching?)

2 years ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

@tomdad How is it all connected/controlled. The heat pump can only produce water at one temperature at any one time, so either it's all running at...

2 years ago
Reply
RE: Bathroom Radiator replacement

Yes. Just find any radiator catalogue eg myson or stelrad and look it up. This will give you W at a DT of 50C between flow temp and room. To conver...

2 years ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

The radiator output at any given ft will increase if the radiator is larger. So larger rads will translate to lower ft (for the same house temperatur...

2 years ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

@tomdad Here is some more detail. Firstly your heat pump is capable of operating at 55 or 35 or anywhere in between and indeed for a bit either si...

2 years ago
Reply
RE: Bathroom Radiator replacement

Thats the main consideration. You need to calculate btu or kW at your design flow temperature and compare with the room heat loss. Towel rails emit...

2 years ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

The point to understand is that cycling basically occurs because the heat demand from the house is less than the minimum that the compressor can produ...

2 years ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

That's a bit of a red flag. I don't think your WC settings are correct. No panic because the heating season is more or less over but some tweaks dur...

2 years ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

A couple of things: 1. You should be running on weather compensation (WC) so that the FT reduces as the outdoor temp increases. Your installer shou...

2 years ago
Reply
RE: Questions on my Hitachi Yutaki SCombi Heat Pump

OK, thats good and low. With low flow temperatures like this there is less to be gained by operating weather compensation than if you were operating ...

2 years ago
Reply
RE: Questions on my Hitachi Yutaki SCombi Heat Pump

Can I suggest you read (if you havent already) this 'starters guide' to heat pumps? I think you may be getting things confused. Firstly dont wo...

2 years ago