RE: Help me keep the faith with my air source heat pump installation

My single Mitsubishi ilife2, which is otherwise perfection, suffers from exactly this problem and the threshold (30C) isn't adjustable. I've just (ye...

3 weeks ago
Reply
RE: Help me keep the faith with my air source heat pump installation

The first chart in your post above shows average 0.25kWh consumption. The second confirms that the unit is delivering less than 1kW output. Yet the ...

3 weeks ago
Reply
RE: Help me keep the faith with my air source heat pump installation

You should be getting better than that at this time of year even though it will be cycling, unless it's really cycling a lot (short cycling). Can you...

3 weeks ago
Reply
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?

I run my Vaillant on either expanded mode (either end of the season when solar gain is a 'problem') or no room influence. Certainly on 'no room influ...

3 weeks ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

You are correct you dont need the second pump if there is no LLH/Buffer (unless there is a 'head' problem with your downstream system) Its entirely ...

3 weeks ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

He may need to tweak a couple of settings. There is definitely on the r290 a setting for no system separation/buffer/llh. Don't know what it does (I...

3 weeks ago
Reply
RE: Odd noise in our Ideal Logic ASHP

I love (and will use) that analogy!

3 weeks ago
Reply
RE: Low COP and unevenly heated rooms with 12kW Samsung AE120MXTPEH / AE260TNWTEH

Where is the noise coming from. If its the pump then perhaps somehow put some insulation around the pump. If its the rads, is it the valves. or the ...

3 weeks ago
Reply
RE: Automation options to maximuse efficiency & ToU tariffs

If you are asking what is available to the non geek householder to optimise for ToU tarrifs, its Homely, Havenwise or Adia. To the best of my knowled...

3 weeks ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Yes. I expect Grant specify a 'minimum system volume' which is the minimum permitted engaged (ie open) volume including the volumiser. Most manufact...

3 weeks ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Which is logical, albeit 30l is a bit small. The manual it seems is clear which trumps anything the installer says and TBH anything the grant helpli...

3 weeks ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Volumiser totally different to buffer or llh. Volumiser 2 ports, buffer/llh 4, volumiser doesn't cause system distortion, doesn't penalise COP, buffe...

3 weeks ago