Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Estimable Member
Joined: Feb 22, 2026
Last seen: May 25, 2026
Topics: 1 / Replies: 91
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

If you tweak the lockshields you'll unbalance the rads so nope. Just TRVs open. It's a simple sanity check. If I read correctly you used to have 30l...

2 months ago
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

The tank used as volumizer behaves like a portion of extra large diameter pipe, it has negligible flow resistance and pressure drop, no worries about ...

2 months ago
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

I think recent versions of the Yonos Pico can display both pressure drop and flow rate in m3/h, if yours does that, you can check the flow will be suf...

2 months ago
Reply
RE: Designing heating system with air to water heat pump in France, near Lyon

The heat pump is humming along, I talked to the neighbors, they said they saw it but didn't hear it, asked if this thing is even on? Not even in silen...

2 months ago
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

Yeah that's the idea, it's dead simple. Personally I'd put it on return instead of flow, as the lower temperature minimizes heat loss from the tank ...

2 months ago
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

I had issues with similar temperature probes, the error can reach a few degrees, which matter in your case since the temps are pretty close. Best ac...

2 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

Yup. As an engineer, perhaps the most important part of my job is to put my foot in it. Toxic positivity is deadly. You have a situation that is, ...

2 months ago
Reply
RE: Why Are Hydronic Ducted Fan Coils So Hard to Source in the UK?

Here in France fan coils are pretty rare for residential so when I contacted distributors they simply didn't want to talk to private individuals lol ...

2 months ago
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

I assume the Wilo pump in the photo is on the load side, not the heat pump side. In this case changing the settings on the Wilo will not influence t...

2 months ago
Reply
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?

Every power conversion circuit has an optimum efficiency point. At low load, power required by the circuit itself becomes a significant part of the to...

2 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

Bullshit. Rubber hoses do let in some oxygen, but that oxygen will travel in the circuit to corrode iron somewhere else. Just because some O2 enters...

2 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

You can get an idea of what these shavings are: They're not rusty, so not steel. You can always try with a magnet. Crush it with some pliers to ch...

2 months ago