Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Reputable Member
Joined: Feb 22, 2026
Last seen: Nov 25, 2026
Topics: 2 / Replies: 224
Reply
RE: Grant Aerona 3: Recommended Water Pressure

1 bar is a column of water 10m high, so the minimum pressure on the ground floor should be high enough to make sure water reaches all the way to the h...

3 days ago
Reply
RE: Hot water tank lose heat rapidly on random days

I hope the installer will agree to come fix it as part of warranty, since the issue was most likely present from the beginning...

4 days ago
Reply
RE: Hot water tank lose heat rapidly on random days

If you want to be 100% sure you can put another temperature probe on the return from the DHW tank. When cold water enters the tank, hot water should e...

5 days ago
Reply
RE: Hot water tank lose heat rapidly on random days

  Pressure rises a lot in sync with water temperature. It should not rise that much. Your expansion tank is not doing its job. Normally as wate...

5 days ago
Reply
RE: How accurate was your heat loss survey?

LOL Same. I did the heat loss by monitoring how long the old heat pump was running per day, which directly gave power in kWh/day since it was an o...

5 days ago
Reply
RE: Hot water tank lose heat rapidly on random days

Even when it is not operating, the heat pump will turn its circulator on periodically: - To prevent it from getting stuck, especially in summer - ...

5 days ago
Reply
RE: Resilience

If batteries are AC coupled with the PV inverter it's more complicated to make it work offgrid reliably versus DC coupled on a hybrid inverter so watc...

1 week ago
Forum
Reply
RE: Resilience

Problem with generators is the same as anything that is rarely used but still needs regular maintenance: if no one is paid to do it, when you actually...

1 week ago
Forum
Reply
RE: Buffer tank on a 2 x 14kw Ecodan system

Higher flow means more turbulence which makes the heat exchange more efficient (also uses more electric power for the pump)

1 week ago
Reply
RE: Buffer tank on a 2 x 14kw Ecodan system

These heat exchangers are specified for Power at a certain deltaT and flow on both sides. DeltaT is the temperature difference between both sides of...

1 week ago
Reply
RE: Resilience

Yes I put 20kWh Pylontech's on the PV inverters. I find it ridiculous that most PV installations, even new ones installed today, even ones with ba...

1 week ago
Forum
Reply
RE: Why don't people choose heat pumps?

Cost of natgas in France tax incl: 0.19€/kWh up to 4000kWh/year, 0.16€/kWh above that, plus 360€/year subscription fee Cost of electricity: 0.15-0.1...

1 week ago