Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Estimable Member
Joined: Feb 22, 2026
Last seen: Jul 26, 2026
Topics: 1 / Replies: 138
Reply
RE: Samsung heat pump - data cable issue

That's well done. Cable is the correct type (LIYCY = 2x stranded copper wires + copper braid shield). The zip tie holds the cable itself, there is no ...

2 days ago
Reply
RE: Samsung heat pump - data cable issue

+1 CAT5 and 6 work absolutely fine for RS485 until the wires break, which will happen eventually if vibration is present or someone opens the panel ...

3 days ago
Reply
RE: My Week with ATW Cooling

Heat of vaporization of water is 2.25 MJ/kg (0.625 kWh/kg), this is the amount of heat that must be removed to condense 1kg (or 1l) of water. Dehumidi...

4 days ago
Reply
RE: My Week with ATW Cooling

It's a seasonal fruit, like tomatoes lol I bought 2x mobile 4kW units used last February for 200€ each. Dehumidifier is likely to be underpower...

4 days ago
Reply
RE: My Week with ATW Cooling

These are identical to mobile aircon units (or US style window aircons) you get a compressor and two refrigerant/air heat exchangers in one box. Dra...

5 days ago
Reply
RE: Advice on my Heat Pump Journey: Old Stone Built Detached Cottage

Well deserved! 👌 55°C to the rads is really high, shouldn't be that high if they are oversized. Assuming the heat loss is correct, this shou...

6 days ago
Reply
RE: Advice on my Heat Pump Journey: Old Stone Built Detached Cottage

OK Power (Watts) = Flow (in l/s) * Heat capacity of water (4180 J/°C/L) * DeltaT (in °C) Flow (in l/s) = Power (Watts) /( DeltaT (in °C) * Heat ca...

7 days ago
Reply
RE: My Week with ATW Cooling

Heat capacity of water is 4180 J/(°C.liter), therefore 1kW = 0.24 °C.liter/s Assuming inlet water temperature 20°C outlet 65°C deltaT 45°C, 1kW cool...

7 days ago
Reply
RE: New Vaillant Arotherm Plus 7kW (cooling enabled) + Jaga Briza cooling + Sunamp Thermino – costs, experiences & Sunamp choice (EnerPHit-level retrofit)

Above dew point cooling is mostly useless. For actual air conditioning you need both cooling and dehumidification which can only be achieved with belo...

1 week ago
Reply
RE: Samsung heat pump - data cable issue

If it is RS485 (is it?)... It uses balanced/differential twisted pair link. The idea is to send the signal on one wire, and the inverted signal on t...

1 week ago
Reply
RE: Samsung heat pump - data cable issue

If it is designed as a RS485 point to point link, then the designers should have included termination resistors on the board at both ends. No idea if ...

1 week ago
Reply
RE: New Vaillant Arotherm Plus 7kW (cooling enabled) + Jaga Briza cooling + Sunamp Thermino – costs, experiences & Sunamp choice (EnerPHit-level retrofit)

+1 for everything Concealed FCUs are expensive to install due to all the drywall work. Also an issue for maintenance. That said, your quote is ind...

1 week ago