Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Estimable Member
Joined: Feb 22, 2026
Last seen: Apr 15, 2026
Topics: 1 / Replies: 72
Reply
RE: Underfloor Heating Installation Issues with Heat Pump

I'm going to install Thermacome ACOSI+ radiant ceiling. It's a French product, so perhaps not available in the UK, but still some important points: ...

1 month ago
Reply
RE: Tell us about your Solar (PV) setup

@mk4 Charge to 100%, discharge down to 10%.

1 month ago
Reply
RE: Daikin Altherma 3 LT compressor longevity question

This mess is intriguing: I wonder if this represents cycling, and if so how long the cycles are. But I don't see cycles on the water temperature c...

1 month ago
Reply
RE: Peak Energy Products V therm 16kW unit heat pump not reaching flow temperature

ASHPs do have a minimum compressor speed. The minimum heat output at that speed depends on air and water temperature. 12kW Vaillant with 45/40°C wat...

1 month ago
Reply
RE: Tell us about your Solar (PV) setup

Location: near Lyon, France 12kWp on the roof, 2x Solis S5 6kW hybrids, 20kWh Pylontech So far pretty good

1 month ago
Reply
RE: Daikin Altherma 3 LT

I wonder what the units are on this plot

1 month ago
Reply
RE: 6 meter run of pipe from the outside to the UniSTOR Pure 200lt cylinder: do I go plastic or copper?

What matters for flow and pressure drop is internal diameter. Thus 32mm MLC (26mm internal diameter) is equivalent to 28mm copper (also 26mm internal ...

1 month ago
Reply
RE: Midea R32 Monobloc MHC-V12W in 1989 Detached House: Noise from Pipes/Airing Cupboard, DHW Schedule Not Always Heating – Advice Needed?

Yes if the circulator is in constant speed mode, the actual flow and pressure are at the intersection of the circulator curve and the heating circuit ...

1 month ago
Reply
RE: Designing heating system with air to water heat pump in France, near Lyon

One can dream! We can Do Our Part by refusing to buy gear that does not expose usable APIs or forces cloud garbage. That's one of the main reasons I...

1 month ago
Reply
RE: Designing heating system with air to water heat pump in France, near Lyon

Designing a good programming language is extremely difficult, very few succeed. Thus application specific languages like HA's automations are red flag...

1 month ago
Reply
RE: Designing heating system with air to water heat pump

Simple: HA automations are awesome for very simple things. However, once it gets even a tiny bit more complicated, then the "programming language" bec...

1 month ago
Reply
RE: Safety update; RCBOs supplying inverters or storage batteries

OK! I dug into it a bit more! Mikeselectricstuff did a teardown of a UK RCBO, it has a tiny current transformer to detect the fault current, then a...

1 month ago