Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Reputable Member
Joined: Feb 22, 2026
Last seen: Sep 5, 2026
Topics: 1 / Replies: 170
Reply
RE: Samsung heat pump - data cable issue

If it's a data cable, current will be minuscule, voltage drop irrelevant. If they run significant current through it then they should call it "power...

2 months ago
Reply
RE: Solar Energy - No Thanks.

In France we had such scheme with wind turbines. Investors own a share of the wind turbine, and cash in a share of the profits, but an overlooked de...

2 months ago
Reply
RE: My Week with ATW Cooling

Office (blue) and Living Room (orange) have UFH, running 18°C water from the heat pump about 12 hours a day (on free PV). Living room also has a mob...

2 months ago
Reply
RE: Surface mount or bury primaries for heat pump installation?

Watts Microflex Duo, intended for burial, about 45€/m, with 2x 26/32mm Barrier PEX. It is quite stiff and difficult to manoeuver but it does the job...

2 months ago
Reply
RE: Hypothetical House Design

The drawing is fine and perfectly understandable except "NRV" which has the symbol of a pump but I guess "NRV" means "Non return valve" or "Check valv...

2 months ago
Reply
RE: Hypothetical House Design

If flow is too low, the heat pump will probably throw a fault. High flow is not a problem for the heat pump, it'll work fine. Higher flow gives lowe...

2 months ago
Reply
RE: Hydrogen Ready

Oh my, bureaucracy at its finest! Does that imply that the reason why both my PV inverters and heat pump have a 8 pin connector with extremely basic...

2 months ago
Reply
RE: Hydrogen Ready

In fact inverters with a bit of local energy storage could also do that, if programmed accordingly. Sadly it doesn't seem the current hardware is prog...

2 months ago
Reply
RE: Hydrogen Ready

I think we're still going to try hydrogen for residential heating on a small scale, then walk it back after a few buildings get launched into low eart...

2 months ago
Reply
RE: Summer heat is becoming the new winter cold in the UK. What are you doing about it?

Hmm I should have explained it better... Problem with these devices: they have only one pipe. Thus they suck in already conditioned air out of the r...

2 months ago
Forum
Reply
RE: Summer heat is becoming the new winter cold in the UK. What are you doing about it?

You guys have it easy It's engineering: calories in, calories out. What I had: stone house, built 1732, 50cm thick walls, estimated thermal mass...

2 months ago
Forum
Reply
RE: Hypothetical House Design

I'd say it's up to you to decide between these two behaviors: * Manual balancing valves * For example Caleffi 132 which has a manual valve and flo...

2 months ago