Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Estimable Member
Joined: Feb 22, 2026
Last seen: Jun 15, 2026
Topics: 1 / Replies: 98
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

I had issues with similar temperature probes, the error can reach a few degrees, which matter in your case since the temps are pretty close. Best ac...

3 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

Yup. As an engineer, perhaps the most important part of my job is to put my foot in it. Toxic positivity is deadly. You have a situation that is, ...

3 months ago
Reply
RE: Why Are Hydronic Ducted Fan Coils So Hard to Source in the UK?

Here in France fan coils are pretty rare for residential so when I contacted distributors they simply didn't want to talk to private individuals lol ...

3 months ago
Reply
RE: Grant Aerona3 13kw - Buffer Tank - Heating Journey

I assume the Wilo pump in the photo is on the load side, not the heat pump side. In this case changing the settings on the Wilo will not influence t...

3 months ago
Reply
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?

Every power conversion circuit has an optimum efficiency point. At low load, power required by the circuit itself becomes a significant part of the to...

3 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

Bullshit. Rubber hoses do let in some oxygen, but that oxygen will travel in the circuit to corrode iron somewhere else. Just because some O2 enters...

3 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

You can get an idea of what these shavings are: They're not rusty, so not steel. You can always try with a magnet. Crush it with some pliers to ch...

3 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

Yeah if you have acidic pH it's going to be bad. I'm baffled at the size of these metal flakes, they're huge! This doesn't look like the usual sludg...

3 months ago
Reply
RE: No spare parts for Vaillant Ground Source Heat Pumps in the UK & major corrosion issue is another problem for GSHP

Here's an excellent explanation. If you have non barrier PEX underfloor heating, it is the most likely culprit as it is permeable to oxygen. Th...

3 months ago
Reply
RE: Heat pump Surge protection

Nominal current is only 0.3A per phase, it's intended to protect public lights, not beefy enough for a heat pump.  

3 months ago
Reply
RE: Aerotherm 12+12kw cascade huge power utilisation

Yeah This may be expensive to fix (or maybe not) you should check your installer contract, see what kind of leverage and/or guarantees you find in t...

3 months ago
Page 5 / 9
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Click to access the login or register cheese
Protected By
Shield Security PRO