Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Reputable Member
Joined: Feb 22, 2026
Last seen: Nov 25, 2026
Topics: 2 / Replies: 224
Reply
Reply
RE: Help me keep the faith with my air source heat pump installation

Flex hoses isolate the main installation from vibrations generated by the heat pump :   Full stainless flex hose Advantages: Lasts foreve...

2 weeks ago
Reply
RE: Buffer tank on a 2 x 14kw Ecodan system

Yeah, someone dropped a bucketload of circulators on this installation. Why? Most likely, you only needed one, or even zero if the tank could have bee...

2 weeks ago
Reply
RE: Buffer tank on a 2 x 14kw Ecodan system

Achieving stratification in a tank is difficult and requires special diffusers on inlets to reduce flow speed and avoid water jets. Here I assume ther...

2 weeks ago
Reply
RE: DIY powerflushing tutorial

Thanks, why didn't I think about the blowtorch 🤣 I used a teaspoon of brown flakes as a sample... Magnet: a small percentage (<5%) of ...

2 weeks ago
Forum
DIY
Reply
RE: DIY powerflushing tutorial

I didn't throw it away. Is there a way to determine what it is?

2 weeks ago
Forum
DIY
Reply
RE: DIY powerflushing tutorial

What came out of the UFH loops is rust from oxygen seeping through the non barrier UFH loops and corroding the old cast iron boiler. There was no slim...

3 weeks ago
Forum
DIY
Reply
RE: Hydrogen Ready

Indeed it is quite idiotic Many industries require pure hydrogen for chemical reactions, it is used in enormous quantities to make fertilizer, steel...

3 weeks ago
Reply
RE: DIY powerflushing tutorial

Interesting! I toyed with the idea too. But I installed a wood burning boiler with its enormous companion tank along with the heat pump, so I'm going ...

3 weeks ago
Forum
DIY
Reply
RE: New Build 3 Phase or 1Phase

Note if you have a PV inverter and either sun or charged batteries, and the electricity provider is limited to 25kVA, your actual limit before it trip...

1 month ago
Reply
RE: New Build 3 Phase or 1Phase

Main issue with 3 phase at low power (16A per phase) is that... you get 16A per phase. So if you plug two 10A single phase appliances on the same ph...

1 month ago
Reply
RE: How quickly would you want/expect heat recovery to take from setback?

Much longer than that here. The heating isn't even on.  

1 month ago