Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Nov 3, 2026
It would be nice to map the flow and return pipes and get some accurate lengths. Perhaps OP can discover a convenient way to split or loop the long 15...
With a bit of persuasion, a SPICE circuit simulator will do hydraulics Assuming 5 rads, 8m pipe between rads (8m on flow and 8m on return) and 8m ...
A calibrated heat meter is an option, it is not cheap, but it is still much less expensive than choosing the wrong heat pump...
Flow rate is set by pressure created by the circulator versus resistance from pipes, valves, etc. On most heat pumps, circulator speed is adjustable, ...
Yeah that's normal Copper is expensive, and the kettle is rated for intermittent use, so they're not going to fit a plug and cable rated for constan...
One thing that bothers me with DHW from monobloc A2W heat pump is they quite often want their own cylinder, which usually comes in a big white box wit...
I have installed an EVSE. I'm French, so I have no idea about the bureaucratic red tape or special subsidies you'll get. While it is usually called ...
OK. If you had two different flow temps and were going for 2 heat pumps, I was about to suggest splitting the installation, one high temp heat pump fo...
Is the flow temperature for the rads and the underfloor heating different?
If the goal is to avoid discharging the battery during cheap electricity times, you could use the Solis scheduler (I think it's called "timed charge")
It's a current output CT (33mA output for 100A input or 1:3000) so it should never be used unloaded. It's the opposite of a battery: a battery is a ...
It depends An unloaded current transformer can output a dangerously high voltage which may cause your switch to arc over, or it can cause arcing ins...
- 27 Forums
- 2,811 Topics
- 66.5 K Posts
- 2,593 Online
- 7,217 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
... And that's being generous! I'll tell you a littl...
By SusannaSaunders , 4 hours ago
-
RE: Adding data centre electricity costs to domestic energy bills?
never ceases to amaze me.. Keeping steel works going ...
By Batpred , 5 hours ago
-
RE: Electricity price predictions
great session Reminds me why some politicians can be ha...
By Batpred , 5 hours ago
-
RE: Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
Absolutely agree. The massive Hager CU my vaillant requ...
By Batpred , 5 hours ago
-
RE: Why don't people choose heat pumps?
With a heatpump tariff, it should be cheaper to operate...
By Batpred , 6 hours ago
-
RE: How much of your renewable and home setup would still work if the internet went down?
absolutely agree. even if many providers see that extra...
By Batpred , 6 hours ago
-
RE: Octopussy cosy 6 experience
People who have a Cosy appear generally to be happy wit...
By JamesPa , 9 hours ago
-
I thought the cr*p came first and the biofuel came afte...
By Majordennisbloodnok , 13 hours ago
-
RE: Aerotherm and weather compensation
@jamespa I replied yesterday with detailed readings whi...
By DavidB , 2 days ago
-
RE: Marvel Heating liquidation
@editor This is an important point. each winter, you...
By davidnolan22 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Very nice. we’ve been super soggy here, but rather m...
By Papahuhu , 3 days ago
-
RE: DIY powerflushing tutorial
Interesting! I toyed with the idea too. But I installed...
By bobflux , 4 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews Agree with the others on sequence: loft first...
By mk1234 , 4 days ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
Heating been on for 4 weeks now, continuous. It's 6C o...
By trebor12345 , 5 days ago


