Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bobflux
bobflux
@bobflux
Member
Estimable Member
Joined: Feb 22, 2026
Last seen: Jul 7, 2026
Topics: 1 / Replies: 119
Reply
RE: Cooling with air to water heat pumps

After solar radiation passes through the window, whether it hits a curtain, wall, floor or any other obstacle indoors the result is the same: heat is ...

1 month ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

Interesting, I'm also going to combine a hydronic fireplace and a heat pump. Currently the heat pump is installed, but the fireplace is still boxed in...

1 month ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

Great news then! If your heat exchanger handles it, then it's going to work fine. It needs to handle enough flow and suck enough thermal power from ...

1 month ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

On one hand, if the exchanger, ducts and air flow rate are sized for furnace-temperature water, they may be undersized for heat pump temperature water...

1 month ago
Reply
RE: Heat Pump Operation in Summer - Valliant 7kW

Yes I use the LG to cool the slabs with underfloor heating. It works fine, as mentioned above flow temp needs to be high enough to avoid condensatio...

1 month ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

@batpred Many manufacturers sell only one or two models of heat pump, then add software limits to make intermediate power models. The result is, if...

2 months ago
Reply
RE: Daikin Altherma 3 with Fan Coils in Puglia (Italy)… Sanity Check on System Operation

AH (Absolute humidity) is grams of moisture per volume (or weight) of air. One cubic meter of air weighs about 1.3kg at 20°C sea level pressure. RH ...

2 months ago
Reply
RE: Daikin Altherma 3 with Fan Coils in Puglia (Italy)… Sanity Check on System Operation

If they don't do heat loss, you need another installer. For cooling in summer, there's another subtlety. In cooling mode, a fan coil unit uses a sig...

2 months ago
Reply
RE: UK warm homes plan - how can it be delivered?

- Taxes on businesses are very high, plus bureaucratic and paperwork load incurs a heavy cost - Thus businesses must produce faster shoddier work at...

2 months ago
Reply
RE: Mitsubishi Ecodan not good enough ?

If you put a fan in a pipe you get a much more efficient ducted fan. To get a quiet heat pump you need a fan that spins as slow as possible while movi...

2 months ago
Reply
RE: Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?

Particles floating in the water are a problem with moving seals like air vents or pressure relief valves, they get stuck in between the rubber seal an...

2 months ago
Reply
RE: Heat Pump Pipe Sizing Question

@trebor12345rebor12345 I got the circulator curves from the docs So at full power for deltaT 5°C it wants 10 l/min or 600 l/h ; at th...

2 months ago