Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 18, 2026
Topics: 27 / Replies: 5256
Reply
RE: Large ASHP recommendations for listed house

Its not 'very high' its completely ridiculous. 25kW is still enough to heat 12cu m of water every day, I repeat, what are you gong to use this vast a...

2 years ago
Reply
RE: Large ASHP recommendations for listed house

120kW seems enormous, whats the floor area of the property? I dont understand why DHW needs to increase because the property is listed. 50kW allows...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Its the actual flow rate, after you have bypassed the buffer/pump, that you are interested in. Your controller should have a read out and I would mak...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Yes the bypass is as I sketched, although I should sound the note of caution that, as I don't have a full system diagram, there may be something else ...

2 years ago
Reply
RE: Is My Midea Heat Pump Inherently Defective?

Shouldn't be a problem, in common with many fancoils it has a very short pipe with lots of fins on, not a long pipe. That means it doesn't add much t...

2 years ago
Reply
RE: Weather compensation climatic heat curves

To tweak for low temps I would increase or decrease (as appropriate) the target flow temperature at the minimum outdoor temperature end of the curve.

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

OK thats a bit more reasonable albeit higher than might be expected, and gives some hope, but by no means certainty, that bypassing the buffer and sec...

2 years ago