Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

F1p
@f1p
Member
Estimable Member
Joined: Oct 27, 2025
Last seen: Aug 11, 2026
Topics: 1 / Replies: 121
Reply
Reply
RE: Melpump Users Anywhere?

Thanks for reporting, there is a known issue following a security adjustment

5 months ago
Reply
RE: Setback savings - fact or fiction?

Flow temperature will have a influencing factor too, However, yes, as there is an absence of power monitoring inside i think this formula is how it ...

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

@ecoste your FTC7 has the ability to perform dynamic PWM to maintain DeltaT, is your primary circulation pump is not PWM controlled by the FTC7?Is tha...

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

  Just wanted to mention.. 38% of these devices had an average outdoor temperature of 5-9C and 47% were outside the filter ranges (below 0 or 2...

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

@ecoste Numerically, and i'm sorry if it's obvious to you already:   25L/min @ 2.0 DeltaT = ~3.5kW output so with ~1.17kW input it's a CoP ...

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

@ecoste what happens to DeltaT if you double your flow rate to 30L/min, via the pimary circ pump and also proportionally increase any other zone pumps...

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

@ecoste Here is mine for comparison on the same day: /p> 14 rads - two zones but running in simultaneouslyR410a 8.5kW unit, FTC5 generation

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

Thanks @ecoste , This should help @jamespa with his questions too Well, it appears to be running quite nicely, no cycling as you say... Flow rate on...

5 months ago
Reply
RE: Mitsubishi Ecodan Stats Reporting - Accuracy Worsens In Auto-Adaptation Mode

@ecoste are you willing to share your interactive MELPump Detailed Report from a sample day to help us analyse?

5 months ago
Reply
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?

@toodles Not quite the case, NetZero is free (including the capacity monitoring) but things like automations and diagnostics are part of the NetZer...

5 months ago
Reply
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?

On a slightly different topic, I had a calibration today and it's almost the 1y anniversary of the install Capacity at install was 13.7kW and now si...

5 months ago