Reply
RE: Icy cold weather, weather compensation and consumption

Looks like full recovery of IAT by around 0930 to 20C. Flow temp is 36C, still pulling around 4Kw/h so I am calling that a success. I haven't seen or...

2 years ago
Reply
RE: Icy cold weather, weather compensation and consumption

Fairly similar results here in the Perthshire riviera where we only got to OAT of -7C overnight and recovered a bit to -5C at present. Set back to IAT...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

@cathodeRay Agreed...it sounds like a sensible conclusion even though I have found bats in the most unlikely places. They do hate kerosene though!

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

Well actually... it is perfectly possible to have a bat roost on one wall of a building and not on the opposite, depending on the building location, o...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

I can only comment from a seat on the pants experience of how my system operates but it falls closely within what I perceive to be the test building ...

2 years ago
Reply
RE: New installation not quite right, advice sought

@guthrie My installer left me the entire package from soup to nuts but from what I read here that does not seem to be the norm. May I enquire what ...

2 years ago
Reply
RE: MELCloud Reports

It's failing on DeviceID Expression.Error: There weren't enough elements in the enumeration to complete the operation. Details: [List]

2 years ago
Reply
RE: Weather compensation and air source heat pumps

Hi @Morgan, I am a bit away from you in the hills of eastern Perthshire. I reluctantly switched the servicing away from the very knowledgeable insta...

2 years ago
Reply
RE: ASHP heating issues / error code - advice very much appreciated

Stab in the dark, might it be error P1? This is the system lost thermistor value error. It can be reset in the settings -/p>

2 years ago
Reply
RE: Weather compensation and air source heat pumps

I am afraid that I have never peered too deeply into the settings to find exactly how the curve is configured. The installer spent some time on this p...

2 years ago
Reply
RE: Ecodan Room Temperature Mode

0.5C increments. 2 x AA batteries. Mine have been in use for 4 years and there is no indication they are needing changed. No idea! It seems to p...

2 years ago
Reply
RE: Do setbacks save energy without compromising comfort?

Thank you @cathoderay, this is a very interesting read, not just because my system is not a hundred miles away from your setup, but also in the way th...

2 years ago
Page 15 / 20
Share:

Join Us!

Latest Posts

Members Online

 No online members at the moment

AI Chatbot Avatar
AI Engine
Talk to
Wattson:
AI Avatar
Welcome to Renewable Heating Hub! Ask me anything about heat pumps: how they work, running costs or even how to find installers in your area.

By using this chatbot, you agree to the recording and processing of your data by our website and the external services it might use (LLMs, vector databases, etc.).