Reply
RE: Advice on ASHP choice needed

Heat loss estimates can vary considerably, depending on who is doing them. Have a look at this for a variety of methods including using your gas usage...

8 months ago
Reply
RE: Samsung Gen6 setting I can't fathom: water outlet heated to 64C.

@old_scientist I am on FIT and get 9p/kWh generated. The main financial benefit from my solar panels is from not using the grid, especially at expensi...

8 months ago
Reply
RE: Octopus Energy new Cosy tariff.

@old_scientist Thanks - I have never seen that done before.

8 months ago
Reply
RE: Octopus Energy new Cosy tariff.

Is your volumiser a 2 pipe tank and is it really located in the circuit to the DHW cylinder as well as the circuit to the emitters? A lot of Samsung i...

8 months ago
Reply
RE: Samsung Gen6 setting I can't fathom: water outlet heated to 64C.

The minimum set point for legionella on the Samsung is 40C, so this would not work. However, I don't follow your logic in looking for an alternative t...

8 months ago
Reply
RE: Octopus Energy new Cosy tariff.

I have an oversized 12kW Samsung and similar solar PV. I switched from Cosy to Agile in early October 2023 and have monitored the difference in costs ...

8 months ago
Reply
RE: Samsung Gen6 setting I can't fathom: water outlet heated to 64C.

I would disable the legionella sterilisation (FSV 3041) and there shouldn't be any error messages then. I don't have any.

8 months ago
Reply
RE: My horrific Samsung heat pump installation and experience

This was not my experience. It operated purely as an on off thermostat. I believe that with additional wiring, it does have additional functionality, ...

8 months ago
Reply
RE: Samsung Gen6 setting I can't fathom..........

Hi, the immersion was disconnected from Samsung and the iBoost directly connected to the immersion instead. Therefore there is no connection between t...

8 months ago
Reply
RE: My horrific Samsung heat pump installation and experience

Can you not use the Samsung wired remote controller as your thermostat? If you need to move its location, it is just a question of running a length of...

8 months ago
Reply
RE: My horrific Samsung heat pump installation and experience

My apologies! That behaviour is quite different to my Gen 6 12kW Samsung and to what my manual suggests. Option 0 - just using the thermostat in the w...

9 months ago
Reply
RE: My horrific Samsung heat pump installation and experience

@technogeek FSV 2091/2092 Setting 4 causes the water pump to run 3mins on and 7 mins off, not the heat pump. However, I have no idea why Samsung provi...

9 months ago
Page 6 / 17
Share:

Join Us!

Heat Pump Dramas?

Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.

Pre-Installation Planning
Post-Installation Troubleshooting
Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)

👉 Book a one-to-one consultation now.

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security