Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 10, 2025
Can you not use the Samsung wired remote controller as your thermostat? If you need to move its location, it is just a question of running a length of...
My apologies! That behaviour is quite different to my Gen 6 12kW Samsung and to what my manual suggests. Option 0 - just using the thermostat in the w...
@technogeek FSV 2091/2092 Setting 4 causes the water pump to run 3mins on and 7 mins off, not the heat pump. However, I have no idea why Samsung provi...
@jamespa Yes I totally agree with your comments and you have explained the difference between timed and thermal control very well. I haven't yet worke...
I feel that I need to defend the use of thermostats with heat pumps, particularly in the case of heat pumps that are oversized and don't modulate down...
I am not an engineer, just a Samsung ASHP owner, but everything that I have read suggests that removing the filter is a bad idea. There are two report...
This only happens if a PWM pump is fitted with the appropriate wiring - very unlikely in this case. So adjusting these settings makes no difference to...
You say that you have measured your hourly gas usage during cold days and so have a good idea of your heat load. In which case you already know your h...
@david999 What size is your Samsung? Is it 16kW? If not, 29lpm should be ample flow rate.
Hi @toodles That external insulation looks pretty poor to me, but not unlike my original insulation. Cable ties are definitely not to be recommended. ...
My 50L buffer tank made cycling worse not better. At a LWT of 33C the radiators were only getting 30C due to mixing of the flow and returns in the buf...
Yes, when the ASHP cannot produce less heat than the radiators are delivering, the return water temperature and leaving water temperature (LWT) tend t...
- 27 Forums
- 2,733 Topics
- 64.2 K Posts
- 1,160 Online
- 7,139 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Questions about A2A for heating as well as cooling
Thank you for that very helpful and thorough response! ...
By donciccio , 4 hours ago
-
RE: Aircon - in listed buildings
@etchedpixels thanks for giving such a full and helpful...
By GrahamF , 19 hours ago
-
RE: Acond heat pump failed after four years - diagnostic quote £940 plus VAT
Another idea if the above don't work - there are compan...
By downfield , 21 hours ago
-
RE: Love veg, hate watering cans
They have their downsides but boreholes are great in th...
By ian33a , 22 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist The service engineer powered down the ex...
By Papahuhu , 22 hours ago
-
RE: Issue with Samsung Cascade System
@jamespa It's a funny system, but was out only option l...
By Renewables345 , 1 day ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Thanks, I like the chart, very helpful and this will de...
By baroquebank , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
Production resumed to normal once the issue ...
By MK4 , 2 days ago
-
RE: Digest of UK Energy Statistics
That sounds painful. It would be much better to charg...
By Transparent , 3 days ago
-
Hole diameter is small but hole length is also very sma...
By bobflux , 3 days ago
-
RE: Are Wind Turbines Really “Losers”?
We were sailing near a wind farm in the North Sea last ...
By Jeff , 3 days ago
-
@trebor12345 The idea is to ensure that Powerwall knows...
By Toodles , 3 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
'hard limited' could be in 'admin' password protected s...
By JamesPa , 4 days ago