Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 19, 2026
Topics: 27 / Replies: 5262
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Our posts crossed so please read/re-read mine above also In answer to the question, No, once rads are balanced leave them, and turn down the flow te...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

There are several steps to getting the most efficient settings and you need to have faith to see them all through 1. Disable any external controls (...

2 years ago
Reply
RE: Vaillant Arotherm ASHP gets noisier when it gets colder outside

I've now more or less fixed mine. At night I have enabled noise reduction mode. This does compromise performance when it's at minus temperatures, ...

2 years ago
Reply
RE: Grant Aerona3 R32 HPIDI17 performance in low temperatures

The Vaillant Arotherm R290 does the legionella cycle natively, ie using the heat pump itself. Most (possibly all) R32 heat pumps dont, they use the...

2 years ago
Reply
RE: Totally bewildered with my ECO4 heat pump installation

I actually think its totally unfair to blame the Government entirely, whatever the colour. The fact is that any scheme of this nature (and indeed alm...

2 years ago
Reply
RE: Totally bewildered with my ECO4 heat pump installation

OK so your are getting an COP for the installation of 3.5 since it was installed, 3.6 last month and 2.95 this month. This includes both DHW and spac...

2 years ago
Reply
RE: Ideal Logic 10kW Heat Pump Pipes Noisy and Very Expensive to Run

If the controller box has a temperature sensor (I don't know but the manual should say) do insist they put it somewhere sensible! You may just want t...

2 years ago