Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 20, 2026
A period of on followed by a period of off is one cycle, but only if followed (or preceded) by more on-off periods. One on/off transition on its own ...
Absolutely could be a volumiser and thats what I would recommend if the extra system volume is needed to meet the minimum requirement.
I will answer in a different order in the hope of shedding some light. Before I do though I would make the general remark that, in order to analyse t...
Nothing wrong with a remote on/off switch. I used to use my 40 year old hall thermostat that way when I had a boiler (as a thermostat it was essentia...
You are right, the very low flow temp is the major contributor to good COP. Also, at low flow temperatures, the potential penalty of a buffer is less...
The installers who insist you need a buffer are ones to be avoided. You may need a volumiser which has only 2 ports. These dont suffer the problems ...
OK, let me refine my simplified initial statement. Generally I would recommend that any TRVs except (a) for aesthetic reasons as described above ...
OK that now makes sense, basically both control loops are operating as expected. If you changed the target deltaT to 5 I presume that the heat pu...
@powysperson You don't say what your heating us. If by any chance you have a heat pump don't fit radbots. In most cases don't fit trv tops either...
I agree with the above Fancoiks have a very small water volume and you have a fairly high capacity heat pump in a mild climate. Short cycling is to ...
Sorry I'm still not sure what you are actually observing (what do you see as opposed to what do you think might be the explanation) The heat pump ca...
Difficult to comment. Given the choice I would design for 45 or less and wouldn't accept anyone who won't. I would reject without question anyone wa...
- 27 Forums
- 2,772 Topics
- 65.3 K Posts
- 793 Online
- 7,174 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Next steps on my ASHP journey: Radiators and Pipework
First up once I have a flow meter fitted is to simply m...
By Rob of York , 1 hour ago
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
If they can't don't give up. Heat pumps are, in reali...
By JamesPa , 24 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I wouldn't be too concerned about the design ...
By Rob of York , 1 day ago
-
RE: Missing flow temperature in Heat Geek proposal
Yes that's what would happen by turning down the lsv to...
By JamesPa , 1 day ago
-
RE: Grant R290 DHW Cycle Interuption
It looks like some sort of short pre-run. The question...
By JamesPa , 1 day ago
-
RE: Cascade System or larger single unit
@renewables345 I would say if it a new build it’s no mo...
By Aventus Eco , 1 day ago
-
RE: Why are ASHP installs so expensive?
Posted by: @batpred There´s another aspect that coul...
By Rob of York , 1 day ago
-
RE: Say hello and introduce yourself
@gz00, welcome to the forums. There’s a huge amount of ...
By Mars , 2 days ago
-
RE: Home energy storage & battery register
1 fox ess lv5200 batteries, plus 2 more waiting to be i...
By Jimcub , 2 days ago
-
RE: Heat Pump deployment statistics: June 2026
@l8again Unfortunately the government is, I suspect,...
By JamesPa , 2 days ago
-
My feed of random industrial auctions turned up this au...
By Prunus , 2 days ago
-
Thank you @majordennisbloodnok – that means a lot, part...
By Mars , 3 days ago
-
We’ve just passed 20 million forum views! 🎉
It's official. The Renewable Heating Hub forums have of...
By Mars , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@batpred When the raw material input has increased in c...
By Papahuhu , 5 days ago