Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 17, 2026
Topics: 27 / Replies: 5235
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

Honestly no idea. The simple thermodynamics say that lower DT is always better. I have not heard a coherent explanation why we design for DT 5 not...

1 year ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

Good I guess these operate the actuators on each loop but maybe one on each manifold operates the zone valve? If tyhere is nothing else to set high ...

1 year ago
Reply
RE: Volumisers in Heat Pump Systems: Does Placement Matter?

No, that wouldn't account for the flow temp being lower than the return temp. This shows that the water pump continues to operate and as a result the...

1 year ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

I think what will actually happen is that the deltaT from flow to return will decrease. There may be a slight increase in energy to the house (becaus...

1 year ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

If they arent permanently open then yes they would cause a problem (unless they are all wired to close simultaneously when the DHW comes on - instead ...

1 year ago
Reply
RE: Volumisers in Heat Pump Systems: Does Placement Matter?

Sofaik all others do the same, ie they operate the refrigerant circuit in cooling mode to effect defrost. They thus cool the house and warm the heat ...

1 year ago
Reply
RE: Volumisers in Heat Pump Systems: Does Placement Matter?

Are you sure. Where does the defrost energy come from on that case? Most stop the fan but leave the primary pump going thus extracting the defrost ...

1 year ago
Reply
RE: best approach for primaries?

Personally I would want them inside the heated envelope if possible. Then the heat loss is useful during the heating season. Obviously its a bit sit...

1 year ago
Reply
RE: help with new bathroom and towel radiator

I persuaded my installer that heat loss from the adjacent hallway plus steam when you actually take a bath/shower was sufficient (in order that we did...

1 year ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

@sandman1600 just looking at the plots here it looks to me like there is in fact a range of outside temperatures where it does not cycle, casting doub...

1 year ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

If you think your heat loss is between 4.5 and 8.5, the r290 is probably a goodun because of its.unusually large modulation range, due to having two c...

1 year ago