Search with Wattson
Activity
 
Notifications
Clear all

Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 16, 2026
Topics: 27 / Replies: 5235
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

The radiator output at any given ft will increase if the radiator is larger. So larger rads will translate to lower ft (for the same house temperatur...

1 year ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

@tomdad Here is some more detail. Firstly your heat pump is capable of operating at 55 or 35 or anywhere in between and indeed for a bit either si...

1 year ago
Reply
RE: Bathroom Radiator replacement

Thats the main consideration. You need to calculate btu or kW at your design flow temperature and compare with the room heat loss. Towel rails emit...

1 year ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

The point to understand is that cycling basically occurs because the heat demand from the house is less than the minimum that the compressor can produ...

1 year ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

That's a bit of a red flag. I don't think your WC settings are correct. No panic because the heating season is more or less over but some tweaks dur...

1 year ago
Reply
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?

A couple of things: 1. You should be running on weather compensation (WC) so that the FT reduces as the outdoor temp increases. Your installer shou...

1 year ago
Reply
RE: Questions on my Hitachi Yutaki SCombi Heat Pump

OK, thats good and low. With low flow temperatures like this there is less to be gained by operating weather compensation than if you were operating ...

1 year ago
Reply
RE: Questions on my Hitachi Yutaki SCombi Heat Pump

Can I suggest you read (if you havent already) this 'starters guide' to heat pumps? I think you may be getting things confused. Firstly dont wo...

1 year ago
Reply
RE: Help me keep the faith with my air source heat pump installation

The guy was right as regards buffer tanks, avoid. However a 2 port volumiser is ok. Unfortunately terminology isn't quite consistent. Check that it...

1 year ago
Reply
RE: Is it KISS or constant – weather compensation vs. set flow temperature?

@cliffhanger Mine has a 'space heating off' setting! Otherwise turn down thermostat if you have one and it's set up to call for heat

1 year ago
Reply
RE: Performance of Heat Pumps in Mild Weather

That's a good analysis. Presumably heat pump manufacturers design on the assumption that the heat pump is right sized. The typical oversized heat pu...

1 year ago
Reply
RE: Help me keep the faith with my air source heat pump installation

@adamk Sounds encouraging, what about any independent measure of total loss eg from current gas/oil consumption. Rooms share heat to a fair extent s...

1 year ago
Page 248 / 440
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Members Online

Click to access the login or register cheese
Protected By
Shield Security PRO