Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 16, 2026
@eliuccio Thorough analysis and, tbh, it looks like you have two viable quotes (a good position even if it makes the choice difficult!) Here ...
Cynically I would suggest its there to protect the installer and cost you money unnecessarily (both at install time and in running costs). The smar...
Yes Yes to the first No to the second (I think) as this results in cold return water being swept up into the flow, reducing the flow temp to em...
In addition to the above you might want to balance out the buffer so it is acting as if not there. Adjust pump speeds for minimum difference in temp ...
It sounds like you get it, maximise the load by opening everything up, cancel mixing by setting the mixer valve temp to max, and then batch heat your ...
I'm really sorry to hear that. As others have said this is massively oversized. It is also massively overcomplicated. Taking the two together this...
Hi Just to confirm my understanding. You have an 11kW heat pump and an assessed loss of roughly 2.5kW (118W/K * 20). Is this a correct interp...
Thanks. Just a few more questions to get a handle on sizing What was the date of the plot and what was the approx OAT then? Which model ASHP...
Fundamentally I agree with @mars and yes please post the full system schematic for detailed suggestions. Seriously heat pumps work best when operate...
Thats a brilliant result and you must be pleased you persisted with fighting this. Its also a good example of what I am beginning to suspect (but can...
As you say this is no change, which I personally think is reasonable given the figures in BS 8233.
- 27 Forums
- 2,745 Topics
- 64.5 K Posts
- 625 Online
- 7,148 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
I think I saw a diagram for an exhaust air dhw tank wit...
By JamesPa , 13 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu Of course, in the way of such things, there a...
By Toodles , 20 hours ago
-
@DavidB, I think @Majordennisbloodnok has already naile...
By Mars , 2 days ago
-
RE: Indevolt Batteries UK Support & Info Thread
Thanks, however that's an answer to a subtly different ...
By JamesPa , 3 days ago
-
RE: Flushing system, cleaning and inhibitor
Yes, my 50L volumiser uses the two lower ports, so ther...
By Old_Scientist , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles Such elegant symmetry. look at my lumpy bag of...
By Papahuhu , 4 days ago
-
RE: PV and battery long payback - sense check query
Quite probably not, but you can get a 32A relay and a S...
By JamesPa , 4 days ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s Look forward to making contact soon! Regards, To...
By Toodles , 4 days ago
-
I don't notice mine defrosting, and most of the time Im...
By JamesPa , 5 days ago
-
RE: Do I need to change the control unit when replacing my Ecodan Air Source Heat Pump
Kind of you, @calumm, but it was @f1p who did the heavy...
By Majordennisbloodnok , 5 days ago
-
RE: Electricity price predictions
2. As EV ownershp increases it'll certainly increase de...
By EtchedPixels , 6 days ago
-
I meant to say I cannot register my kit at Energyplus… ...
By Batpred , 6 days ago