RE: Heat pump delta T too low - 2c

@benseb You may need a plumber to install it, once you have done it, you may find the pipe is OK, if not, you can install another pump in series and r...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@mike-h The heating circuit should never be closes, you need to install a 3 port diverter full ball valve, either a Belimo, Esbe or Sintesi (from V Fl...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@mike-h I am doing a presentation on exactly this at PowerXlive in London on wedensday. You will see a significant increase in performance if you remo...

3 years ago
Reply
RE: Heating theory doesn’t match reality

@drdp Hi, Difficult to determine what is wrong, can you PM me a system drawing listing all components and wiring if possible. It does not seam to be w...

3 years ago
Reply
RE: Underfloor heating designer / engineer needed

@transparent This valve will control the flow temperature and on whether compensation and internal temperature, there are others on the market, but th...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@scrchngwsl The ideal Delta T for a heat pump is 8 Deg C. Any variance, either way, will reduce performance. The good units on the market will control...

3 years ago
Reply
RE: Most efficient use of NIBE GSHP with Solar PV

@derek-m The Nibe unit actively monitors the electricity going back to the grid and will raise the water temperature first and then the house temperat...

3 years ago
Reply
RE: Underfloor heating designer / engineer needed

@transparent You have too much micto contro for an efficient system. If you controlled the water temperature and blend it down with a proper temperatu...

3 years ago
Reply
RE: Heat storage batteries

@derek-m The cheapest and best heat energy storage is a thick concrete slab with a well designed low temperature under floor heating system

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@benseb the Delta T should be between 5 and 10 Deg C. Try reduce the speed on one of the circulating pumps. This will increase the Delta T and further...

3 years ago
Reply
RE: Rate the quality of your heat pump design and installation

Mars, I think you are very optimistic and have significantly overstated the number of well designed systems. From the amount of systems that we sort o...

3 years ago
Reply
RE: Underfloor heating designer / engineer needed

@transparent You seam to have a system with a lot of potential. With a few alterations, it will improve conciderably and reduce your running costs. Yo...

3 years ago