In reality, without monitoring equipment installed, it is very difficult to determine the actual, accurate performance of any heating system regardles...
@hydros How is the system being controlled? You mentioned a set temperature, where is that being set? What control do you have on the radiators and ...
@iancalderbank PM me and I will see if I can help.
The heat exchanger failure is a manufacturing fault, nothing to do with operation. If you have a buffer tank or system separation, that is causing y...
@iancalderbank I am not sure if the new Samsung will allow the setting of the Delta T (gather you can install a PWM pump on it), I install the Panaso...
@webcmg Then I am sorry to say, you have an exceptionally badly designed system. I would complain to the installers competent persons scheme and MCS.
In my view, AI should work for you to make your life easier, more comfortable and cheaper. As soon as it starts dictating to me, it goes in the bin.
The usage would be about right for the design and flow temperature, but probably more than double what it should be.
@batalto @chrislay A low loss header is not needed in any installation. We will use a small tank (50 litres) where we will put the 2 heat pump flows i...
@webcmg Do not reduce the pumps to minimum setting, it will significantly increase your heating cost. The water transmits the heat, no water = no heat...
@derek-m 👍
@derek-m but only you can make it work, therefor useless on a wider scale.
- 26 Forums
- 2,360 Topics
- 53.5 K Posts
- 371 Online
- 6,026 Members
Join Us!
Worth Watching
Latest Posts
-
RE: New Fogstar 15.5kWh upright solution
@transparent I have 3 of these units and ex...
By Bash , 9 minutes ago
-
I also enjoy the challenge of getting the best out of s...
By downfield , 12 minutes ago
-
When checking the Met Office website to see what weathe...
By Toodles , 17 minutes ago
-
RE: Speedcomfort radiator fans
&mars SpeedComfort have confirmed my understanding ...
By Richard24738 , 30 minutes ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Hi @mickamills . Welcome to the forum. It sounds like...
By bontwoody , 42 minutes ago
-
RE: External pipework insulation
@transparent I hope you are not being admonished @trans...
By Toodles , 50 minutes ago
-
RE: Setback savings - fact or fiction?
Oops, well spotted, thanks. Yes they are the wrong way ...
By cathodeRay , 1 hour ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@gruff2001 Our Growatt 13 kWh system charges about 11.7...
By ChandyKris , 2 hours ago
-
RE: Mitsubishi Ecodan R290 10kW performance
All noted, Im not doubting you, just trying to be certa...
By JamesPa , 5 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The FT levels off at either the set point OR the minimu...
By AndrewJ , 22 hours ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 22 hours ago
-
RE: Midea ASHP – how to set weather compensation
@pash44pump I have yet to come across any Clivet or Mid...
By benson , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
@transparent Thanks, this helps. Could it be that St...
By Batpred , 1 day ago
-
RE: Clivet ASHPs and weather compensation
Simon did share a lot of very helpful advice. On furthe...
By ambris , 1 day ago
-
-
RE: Advice on internal circulation pump noise
Extend the primary branch and make sure you have more t...
By ASHP-BOBBA , 2 days ago
-
RE: Jokes and fun posts about heat pumps and renewables
By Morgan , 2 days ago
-
RE: Controlling Daikin Altherma via P1P2 and Home Assistant
On the contrary, @toodles, that’s a lot of help. I’d ne...
By Majordennisbloodnok , 2 days ago