Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Brendon Uys
@heacol
Contributor
Prominent Member
Joined: Aug 6, 2021
Last seen: Oct 1, 2025
Topics: 3 / Replies: 411
Reply
RE: AI Heating Controls & IoT

@knukes 🤣 🤣 🤣 🤣 Yes, they all say it cannot be done. We have a report from the university saying it does work but we have a long way to get to commerc...

3 years ago
Reply
RE: AI Heating Controls & IoT

I am working on that, the first prototypes have been tested at a university on a unit that produces heating and hot water which comprises of a box the...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@mike-h I hope you are putting that in inverted commas 🤣

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@benseb You may need a plumber to install it, once you have done it, you may find the pipe is OK, if not, you can install another pump in series and r...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@mike-h The heating circuit should never be closes, you need to install a 3 port diverter full ball valve, either a Belimo, Esbe or Sintesi (from V Fl...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@mike-h I am doing a presentation on exactly this at PowerXlive in London on wedensday. You will see a significant increase in performance if you remo...

3 years ago
Reply
RE: Heating theory doesn’t match reality

@drdp Hi, Difficult to determine what is wrong, can you PM me a system drawing listing all components and wiring if possible. It does not seam to be w...

3 years ago
Reply
RE: Underfloor heating designer / engineer needed

@transparent This valve will control the flow temperature and on whether compensation and internal temperature, there are others on the market, but th...

3 years ago
Reply
RE: Heat pump delta T too low - 2c

@scrchngwsl The ideal Delta T for a heat pump is 8 Deg C. Any variance, either way, will reduce performance. The good units on the market will control...

3 years ago
Reply
RE: Most efficient use of NIBE GSHP with Solar PV

@derek-m The Nibe unit actively monitors the electricity going back to the grid and will raise the water temperature first and then the house temperat...

3 years ago
Reply
RE: Underfloor heating designer / engineer needed

@transparent You have too much micto contro for an efficient system. If you controlled the water temperature and blend it down with a proper temperatu...

3 years ago