Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 1, 2025
In reality, without monitoring equipment installed, it is very difficult to determine the actual, accurate performance of any heating system regardles...
@hydros How is the system being controlled? You mentioned a set temperature, where is that being set? What control do you have on the radiators and ...
@iancalderbank PM me and I will see if I can help.
The heat exchanger failure is a manufacturing fault, nothing to do with operation. If you have a buffer tank or system separation, that is causing y...
@iancalderbank I am not sure if the new Samsung will allow the setting of the Delta T (gather you can install a PWM pump on it), I install the Panaso...
@webcmg Then I am sorry to say, you have an exceptionally badly designed system. I would complain to the installers competent persons scheme and MCS.
In my view, AI should work for you to make your life easier, more comfortable and cheaper. As soon as it starts dictating to me, it goes in the bin.
The usage would be about right for the design and flow temperature, but probably more than double what it should be.
@batalto @chrislay A low loss header is not needed in any installation. We will use a small tank (50 litres) where we will put the 2 heat pump flows i...
@webcmg Do not reduce the pumps to minimum setting, it will significantly increase your heating cost. The water transmits the heat, no water = no heat...
@derek-m 👍
@derek-m but only you can make it work, therefor useless on a wider scale.
- 26 Forums
- 2,714 Topics
- 63.6 K Posts
- 371 Online
- 7,114 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Samsung heat pump - data cable issue
Well that's interesting. If it needs fat cable it's be...
By JamesPa , 32 minutes ago
-
RE: Rate the quality of your heat pump design and installation
I'm kind of at the end of my heat pump installation now...
By JandP , 3 hours ago
-
RE: MCS Quality Audit – Has Anyone Had One? Did It Lead to Remediation?
I got hit with an RHI audit in 2022. It was far from c...
By Abernyte , 4 hours ago
-
RE: Electricity price predictions
@papahuhu Groucho Marx had something to say about no...
By Toodles , 6 hours ago
-
Given the way radiation and convection effects don't wo...
By Majordennisbloodnok , 8 hours ago
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@jamespa haha very true, although the engineer yesterda...
By swwils , 11 hours ago
-
RE: Vaillant Arotherm Pro vs new Plus
One of the test modes in the installer menu forces it t...
By JamesPa , 1 day ago
-
RE: What a difference a few degrees make.
Wow. Having accepted the challenge, I ran the cold tap ...
By Old_Scientist , 1 day ago
-
RE: HeatPump maintenance in Swindon area?
@vince31 have you tried using our finder:/p>
By Mars , 1 day ago
-
Looking for beta testers for a new homeowner heat pump tool
Over the past few months I've been building a brand new...
By Mars , 1 day ago
-
-
RE: Indevolt Batteries UK Support & Info Thread
It depends on how you configure it via the app. The ma...
By JamesPa , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Be interesting if this results in any wider changes to ...
By Jeff , 2 days ago