Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
Looking at the data it would appear that your heat pump is still working and maintaining the IAT during the setback period, so the setback does not ap...
Quite some time ago I created an Excel Modeling Tool with which it is possible to approximate the operating parameters of a heat pump under varying op...
Don't confuse SCOP with COP. You are indeed correct your costs will be much higher in Winter than in Summer, not just because you are using more ele...
Having just read your original post I feel there is need for clarification. If my understanding is correct, SCOP is the 'seasonal' coefficient of pe...
@graeme You may find the following link of use.
Improved insulation will have an impact on both COP and SCOP, since reducing the thermal energy demand should improve the efficiency. The simple fac...
In an ideal world a heat pump unit would contain two compressors, a nominal 12kW capacity heat pump having one compressor rated at 8kW and one compres...
@jamespa I fully agree with James that a HT heat pump will probably be no more costly to run than a LT heat pump when operating at the same LWT. I...
It is difficult to assess from just a small section of the data, but the rated capacity of a heat pump is based upon the thermal energy output, not th...
@irmartini The heat loss calculation should detail the estimated amount of thermal energy required each hour to keep the rooms at the specified temp...
Some photo's of your system may be of use in resolving your problem. Before the system was changed did you have one dual rate meter or two single rate...
As more consumers install EV chargers, Heat Pumps and even battery storage, this may help reduce phase imbalance, if they are evenly spread across the...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,965 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Cooling with air to water heat pumps
A quick update. I finally found a 'solar' roller bli...
By springswood , 31 minutes ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
85kWh of gas usage, divided by 24 gives 3.54kW and adju...
By Old_Scientist , 1 hour ago
-
New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
I am feeling baffled and worried:We are having a an Aro...
By GutoFfowc , 12 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 15 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 15 hours ago
-
RE: Questions about A2A for heating as well as cooling
@donciccio I would suggest that you take a "fabric-fi...
By Rob of York , 15 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 1 day ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 2 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Swings and Roundabouts, you win some…. ...
By Toodles , 2 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 3 days ago