Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
As far as the gauge or thickness of the cable is concerned, this will depend upon the maximum quantity of power to be moved and the voltage. If you ...
This method has been tried, but failed. You may have greater success. Unfortunately Ian is reluctant to make any physical changes to his system. Th...
@transparent It is actually referred to as 'combined cycle operation' rather than 'closed cycle operation'. We did have a system as you suggest, i...
@mellow While it may have a label stating buffer tank, it appears to be piped as a volumiser.
@iantelescope I would suggest that you check the Chemistry of the water within your system.
@mellow I doubt that it is a buffer tank if you do not have a secondary water pump, since the system would struggle to work correctly. It may be a v...
It could even be that the present radiator size is adequate, and that the flow rate has been reduced with the lockshield valve to lower the temperatur...
@iantelescope Electric motors, by their very construction and operation, present a predominantly inductive load rather than a capacitive one, so I f...
@gunboatdiplomat From my limited knowledge an actual buffer tank can have quite a number of possible pipe connections with unused ones simply being ...
The blue line is how much thermal energy the heat pump should provide, the red line is how much electrical energy the heat pump would be using.
I think that what you are failing to appreciate is that the required LWT is dependent upon the actual heat loss and heating capacity of the heat emitt...
- 26 Forums
- 2,610 Topics
- 60.8 K Posts
- 139 Online
- 6,967 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Anyone concerned about GivEnergy?
Many thanks for the link, Mars. I have read the relevan...
By KevH , 16 minutes ago
-
RE: Home automation and the cloud; is there a better way?
+1 It's not just cloud though. Many devices have repl...
By bobflux , 2 hours ago
-
RE: End-of-Life Heat Pumps: How Do You Dispose of an ASHP in the UK?
We've started to document everything, and part 2 of the...
By Mars , 8 hours ago
-
RE: Summer usage. Why is my Vaillant Aerotherm using so much energy on "heating"?
So the red bars are 'DHW' and the yellow bars 'heating'...
By JamesPa , 9 hours ago
-
Its good kit the Midea and significantly cheaper, you w...
By ASHP-BOBBA , 12 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Have you tried cutting the grid feed to see what actual...
By JamesPa , 12 hours ago
-
Contractors pack for inta antifreeze valves are around ...
By ASHP-BOBBA , 12 hours ago
-
RE: Renewables & Heat Pumps in the News
Critics and naysayers will be negative whatever the gov...
By JamesPa , 12 hours ago
-
RE: Microbore heat pump installs
In principle you are almost certainly right, but in pra...
By JamesPa , 23 hours ago
-
RE: Electricity price predictions
@old_scientist We are a low mileage home, so bulk of ou...
By ChandyKris , 24 hours ago
-
There are just too many unknowns for me to comment on p...
By Transparent , 1 day ago
-
RE: What is the main ‘dictator’ of Agile’s unit price?
@toodles I keep an eye on wholesale prices and energy m...
By ChandyKris , 1 day ago
-
RE: Brand and installer questions for ASHP
Strange, perhaps it doesnt use modbus which the third p...
By JamesPa , 1 day ago
-
RE: Upgrading my system, how far do I go?
For comparison, my PW3 with 11.04kW inverter, will char...
By Old_Scientist , 1 day ago
-
RE: Changes to Tesla Powerwall Charging Regime?
Elon gate - legendary! I take my hat off to you @toodle...
By Old_Scientist , 1 day ago
-
RE: Mitsubishi Ecodan not good enough ?
Thanks @goody, appreciate the feedback and sorry you ha...
By marcexec , 2 days ago
-
RE: Minimum and Zero Disrupt Heat Pump Installations
True (first sentence) Thats the reason to consider th...
By JamesPa , 2 days ago
-
RE: High air source heat pump running costs – Vaillant AroTherm Plus
Quite right. I was using a rough guesstimate of doublin...
By Majordennisbloodnok , 2 days ago
-
RE: My Grant R290 9kW Heat Pump Installation
Again, really don't know how accurate this is! &nb...
By petch , 3 days ago
-
RE: MCS Quality Audit – Has Anyone Had One? Did It Lead to Remediation?
@toodles The whole scheme is a shocking waste of money....
By Papahuhu , 3 days ago
-
RE: DIY or Don’t Touch? Solarman Smart Meter Install
Yes, and these guys would probably be my preferred inst...
By Batpred , 3 days ago
-
RE: Hot water tank lose heat rapidly on random days
@jamespa Hopefully their reasons are well intended! ...
By Bash , 3 days ago
-
RE: Ecoflow UK Support & Info Thread
As mentioned above, we’ve got our full review of the Ec...
By Mars , 3 days ago
-
RE: Say hello and introduce yourself
@sonosppp welcome to the forums. I see you've posted in...
By Mars , 4 days ago