Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

bontwoody
bontwoody
@bontwoody
Contributor
Noble Member
Joined: Mar 5, 2022
Last seen: Oct 5, 2026
Topics: 39 / Replies: 1021
Reply
RE: Vaillant Arotherm Settings for New Installation

@drew-pa Thanks Drew that isn’t how I understand it. To me the curve sets the “gradient” on the weather compensation chart. The desired room temp...

2 years ago
Reply
RE: Microbore Central Heating Plumbing, will it be a barrier / pain?

The microbore pipes might not be an immediate no-no, but some investigation would be needed as to whether they would work along with the radiators. He...

2 years ago
Reply
RE: Vaillant Arotherm Settings for New Installation

@drew-pa It is set on pure weather compensation at internal temperature of 22C. The unit runs 24hrs with a setback overnight. Theoretically that sh...

2 years ago
Reply
RE: Vaillant Arotherm Settings for New Installation

@hcas Hi , I appreciate the problems with comparing different systems, but this installation is relatively simple with no buffer/LLH. The estimated SC...

2 years ago
Reply
RE: Vaillant Arotherm Settings for New Installation

@hcas Ive opened all but the bedroom radiator valves, which they want to be cooler. Im running my Samsung at about 42C flow at the moment and still...

2 years ago
Reply
RE: Vaillant Arotherm Settings for New Installation

@drew-pa Ive attached the performance estimate Drew, that is all I have. There is no UFH. Also attached are some images of the installation. Other t...

2 years ago
Reply
RE: Vaillant Arotherm Settings for New Installation

Hi Drew. Thanks for the reply. I’ll post his installation details asap. The work is neatly done and all the radiators were changed as per the insta...

2 years ago
Reply
RE: Vaillant Arotherm Settings for New Installation

Just to say, that we have managed to set up the unit now. 22C target indoor temperature and a heat curve of 0.6. High internal temp but the wife is a ...

2 years ago
Reply
RE: Issues with installer's use of pipework for Vaillant Arotherm ASHP

@jwilliams89 Your calculations look good at a glance. With respect to the internal pipe strengtheners, I have tended to use the hep2o ones which are s...

2 years ago
Reply
RE: Issues with installer's use of pipework for Vaillant Arotherm ASHP

Hi. There isn’t anything wrong with using plastic pipes as long as they meet the needs of the emitters. See this by John Cantor. I’ve used them in my ...

2 years ago
Reply
RE: Pre-install Air Source System question.

Hi @essgeesee Welcome to the forum. Heat pumps work best without zoning or TRV's turning radiators on and off regularly. The way a lot of us use our...

2 years ago