Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 16, 2026
@transparent @algienon If the batteries were DC coupled rather than AC that might help get it past the DNO as only the inverter could export. It did...
@algienon Welcome Algie, it sounds like you have great backbone for your installation with all the insulation you have added. A couple of comments o...
@graeme I think the variation might be more than you might think. As you say location is an obvious factor but perhaps 'degree days' could be used to ...
I’m in a similar situation to you regarding energy production, but the seasonal difference in SCOP would vary greatly between houses and locations. We...
@toodles I could add about the time, I set fire to the new sofa after leaving it too close to the 'new' gas fire! I still dont know how my parents did...
Some fond memories there Toodles! 🙂
@drew-pa Ah thanks. Good to know I dont have a misconception about it. On Energy Stats Uk Mick Wall gives a rough way of setting the correct curve. ...
@drew-pa Thanks Drew that isn’t how I understand it. To me the curve sets the “gradient” on the weather compensation chart. The desired room temp...
The microbore pipes might not be an immediate no-no, but some investigation would be needed as to whether they would work along with the radiators. He...
@drew-pa It is set on pure weather compensation at internal temperature of 22C. The unit runs 24hrs with a setback overnight. Theoretically that sh...
@hcas Hi , I appreciate the problems with comparing different systems, but this installation is relatively simple with no buffer/LLH. The estimated SC...
@hcas Ive opened all but the bedroom radiator valves, which they want to be cooler. Im running my Samsung at about 42C flow at the moment and still...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,236 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Not a problem; that’s why I left it as it was. The pers...
By Majordennisbloodnok , 10 hours ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 19 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 2 days ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 2 days ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 2 days ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 2 days ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 2 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 3 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 3 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 4 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 5 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 5 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 6 days ago