Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 16, 2026
@toodles Did you enter your details on the website? Thats what I did.
@editor Fine, the chap was from Fishguard, I think he was more interested in the solar panels and battery than the heat pump, though I did my best to ...
@blaine_t I cant see the examples, but I suspect its probably one of two things, either the heat pump cant modulate down low enough for the houses ...
@toodles @editor I had a visit through it a couple of weeks ago. 🙂
@project_electrify Im not an installer but I would imagine they could just replace the first section of the 22mm with 28mm so that say 3kW of radia...
@project_electrify Yes you can have different pipe sizes. The 10mm copper can move over 1100 Watts at a flow of 0.9 m/s and DT5 (the usual paramete...
I think the next generation of forecasts will probably be AI driven
@ivanopinion Im in the same team as Ivan. I think for all their "picking the lowest hanging fruit", it is the way to get heat pump adoption mainstream...
I’m not an expert regarding noisy installations but I installed my own 5kW Samsung and we don’t hear a peep from it. A couple of things come to min...
@jwilliams89 I would imagine that the MCS would insist on fitting a heat exchanger to the Mixergy anyway, so if you knew when people were coming you c...
@jwilliams89 Can I throw in a left of field alternate option? If you are considering export and TOU tariffs for import, consider a Mixergy cylinder ...
@transparent Good points! Do you know if because of the over supply of renewables in Scotland the export prices are reduced there? If they were, th...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,489 Online
- 7,158 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
Not a problem; that’s why I left it as it was. The pers...
By Majordennisbloodnok , 9 hours ago
-
RE: To re-pipe or not to re-pipe? Moving from oil boiler to air source heat pump.
@penval, really useful update. After all the discussion...
By Mars , 18 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@papahuhu I prefer to look at it simplistically. We d...
By Old_Scientist , 2 days ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 2 days ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 2 days ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 2 days ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 2 days ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 3 days ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 3 days ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 3 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 4 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 5 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 5 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 6 days ago