Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 4, 2025
i’ll join you. Heat pumps aren’t special, they are just another heat source for a heating system boiler manufacturers use the same compensation c...
@webcmg why did you want heat in the radiators…the whole point of any heating system is to have warm rooms, NOT hot radiators!
@derek-m the difference is of course what happens in your industry stays in your industry, but what happens in the heating industry leaves a wake of u...
@derek-m we do ask and nothing happens. Genuinely whilst are regulatory standards are not in line with the manufacturing countries, nothing will chang...
yes a lot of more engaged installers are is in despair. Over the years there have been efforts to engage manufacturers and update training. it meets ...
As an installer i can assure you there is no training on weather compensation, its correct application and the multitude of parameters anywhere. Those...
@kev-m a circulation pump is used to circulate hot water around a loop to reduce the wait at a tap. presumably the cylinder has moved further away fro...
Radiators all are sized for peak load AND a rapid heat up time. If the rapid heat up time is designed out with weather compensation there is no need t...
if that is not happening then opportunities for efficiency are lost two ports create standing losses ie wasted heat they can be used with the rig...
The key to optimising energy efficiency with a heat pump and condensing boiler is constant flow with variable temperature. Thus as room temperature ri...
i stop looking when i see two port valves and i’m a 62 year old heating engineer. high efficiencies can only be delivered with constant flow and varia...
@london-trader really it depends on floor structure. ceramic tiles on screed can have a curve as low as 0.2 or 0.1 also make sure the time windo...
- 27 Forums
- 2,792 Topics
- 66 K Posts
- 2,711 Online
- 7,196 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: battery storage without solar
In general, you're right. However, the law on electrica...
By Majordennisbloodnok , 34 minutes ago
-
Worth a back of an envelope calculation. The specific...
By JamesPa , 41 minutes ago
-
RE: Do You Need a Buffer Tank or Low Loss Header for Underfloor Heating in a Large Property?
@jamespa in some cases, failing the Turing test might b...
By GrahamF , 1 hour ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
@energystoragetech The heat capacity of some...
By JamesPa , 3 hours ago
-
RE: tepeo ZEB UK Support & Info Thread
Sorry you are correct, I was remembering figures from t...
By JamesPa , 12 hours ago
-
Fair enough, still worth checking, I suspect muck gets ...
By JamesPa , 19 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
Our episode with George Clarke and ScottishPower’s Rob ...
By Mars , 20 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
I installed during the era of RHI, not BUS so it doesn'...
By Abernyte , 20 hours ago
-
RE: Review your electricity provider
@singlespeed I seem to remember that when I signed up f...
By Toodles , 20 hours ago
-
RE: [Update] Indevolt PowerFlex 3000: UK ENA Listing Status
Hi everyone, We’ve seen a few discussions and inqui...
By Indevolt Tech , 1 day ago
-
RE: Cooling/heating with one unit
Long term, it may be more cost effective to get an A2A ...
By Rob of York , 1 day ago
-
RE: Renewables & Heat Pumps in the News
Posted by: @editor I think we should make that approa...
By Rob of York , 2 days ago
-
RE: Does anyone have experience of a smart water meter?
My neighbour received an email from Anglian Water sayin...
By AndrewJ , 2 days ago
-
RE: Jokes and fun posts about heat pumps and renewables
Well the military is well known for going green, isn't ...
By Majordennisbloodnok , 2 days ago