Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Oct 2, 2026
@adamk check the temp sensor specification, +/-0.5C may be the accuracy of it.
@simonf no sensor is accurate unless calibrated, I ran the calibration cell in the test laboratory at Gaydon Proving Grounds for a few years; everythi...
@dr_dongle sounds like an adventure. Ive been in Automotive Electronics all my career, I just rewired my Audi to accept Heated Seats; if you didnt kno...
My Cosy6 heat output was 116kWh yesterday, giving an average of 4.8kW/h. Temperature here dipped to -5C last night, coldest so far. COP has dropped ...
@transparent The warm deck roof 150mm thick, eventually a second layer of wool insulation will go up with the ceiling boards The front extension...
Yes, the builder reminded me to allow a good air gap, have 50mm gap up to the top of roof pitch. always good to state the obvious incase some newbie...
As you have maximum floor insulation, there will be little heat coming into the loft area from below, and in summer there will be a large solar gain f...
Last night was a good test whether your ASHP was specified correctly to your house heat loss. I’m at 52 degrees North, Central England, OAT levelled...
Just had my annual service by Octopus. The engineer replaced the pcb in side the Cosy6 without me prompting him. I asked what the new PCB did, all h...
@transparent “the 15kWh battery being discharged at the maximum 100A (5kW) would therefore last 3-hours.” 15kW would only last 2h42m as discharge ...
@majordennisbloodnok I am considering increasing my battery from 5 to 10kW, I’ll ask the installer if when you do that the time take to charge both ba...
@majordennisbloodnok I have the growatt SPA3000TL, it’s not hybrid, spec says charge rate is 3kW and that’s what it does. It also discharges at 3kW ma...
- 27 Forums
- 2,792 Topics
- 66 K Posts
- 3,633 Online
- 7,197 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump branding. Clever, contemporary… or a bit too much?
I think Heat Geek have done an amazing job on their bra...
By Tomtheheatingengineer , 7 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
I have just had 3 heat loss surveys, one by heat geek o...
By David , 7 hours ago
-
RE: Heat Geek Zero Disrupt: Are We Sleepwalking Into Another Race to the Bottom?
I think that's the key question. After all inverter uni...
By Prunus , 8 hours ago
-
RE: battery storage without solar
As of October 1st they need specific qualifications to ...
By EtchedPixels , 9 hours ago
-
RE: How should the Boiler Upgrade Scheme be reformed?
A unit which uses water to transfer the heat/chill from...
By Temperature_Gradient , 10 hours ago
-
RE: Renewables & Heat Pumps in the News
With regards to the BUS grant raid, I gave it more thou...
By ASHP-BOBBA , 10 hours ago
-
RE: Why are ASHP installs so expensive?
The whole system seems to work on the basis of...
By ian33a , 10 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
Good plan. If you can get half hourly meter readings a...
By JamesPa , 15 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@editor Most certainly. The heat pump was an ideal s...
By Abernyte , 16 hours ago
-
Although regulations may well vary from country to coun...
By Majordennisbloodnok , 16 hours ago
-
RE: Does anyone have experience of a smart water meter?
Yep I caught our slow leak from a £100 bill rise 8)
By EtchedPixels , 16 hours ago
-
RE: Do You Need a Buffer Tank or Low Loss Header for Underfloor Heating in a Large Property?
@jamespa in some cases, failing the Turing test might b...
By GrahamF , 19 hours ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
@energystoragetech The heat capacity of some...
By JamesPa , 21 hours ago
-
RE: tepeo ZEB UK Support & Info Thread
Sorry you are correct, I was remembering figures from t...
By JamesPa , 1 day ago
Members Online
No online members at the moment


