Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 14, 2026
@papahuhu absolutely correct, if you change 2 parameters, you cant prove which one made the difference. If you close a window and put the heater from ...
@kevh cant notice any difference, I have a better COP at lower temperatures, can speculate they did something to the efficiency curve?
@adamk check the temp sensor specification, +/-0.5C may be the accuracy of it.
@simonf no sensor is accurate unless calibrated, I ran the calibration cell in the test laboratory at Gaydon Proving Grounds for a few years; everythi...
@dr_dongle sounds like an adventure. Ive been in Automotive Electronics all my career, I just rewired my Audi to accept Heated Seats; if you didnt kno...
My Cosy6 heat output was 116kWh yesterday, giving an average of 4.8kW/h. Temperature here dipped to -5C last night, coldest so far. COP has dropped ...
@transparent The warm deck roof 150mm thick, eventually a second layer of wool insulation will go up with the ceiling boards The front extension...
Yes, the builder reminded me to allow a good air gap, have 50mm gap up to the top of roof pitch. always good to state the obvious incase some newbie...
As you have maximum floor insulation, there will be little heat coming into the loft area from below, and in summer there will be a large solar gain f...
Last night was a good test whether your ASHP was specified correctly to your house heat loss. I’m at 52 degrees North, Central England, OAT levelled...
Just had my annual service by Octopus. The engineer replaced the pcb in side the Cosy6 without me prompting him. I asked what the new PCB did, all h...
@transparent “the 15kWh battery being discharged at the maximum 100A (5kW) would therefore last 3-hours.” 15kW would only last 2h42m as discharge ...
- 27 Forums
- 2,775 Topics
- 65.4 K Posts
- 4,728 Online
- 7,180 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Is it just me, or does tradesperson timekeeping and communication drive you absolutely mad?
Yes, and I would suggest likely to get worse with more ...
By Batpred , 3 hours ago
-
RE: Electricity price predictions
This topic seems more suitable for this thread... I a...
By Batpred , 3 hours ago
-
RE: Why are ASHP installs so expensive?
It is clearly difficult to say, there must be cases whe...
By Batpred , 4 hours ago
-
RE: Who's your electricity provider and what's your tariff?
Hi all, I'm new to this game having spent the last 25...
By gz00 , 5 hours ago
-
RE: Panasonic Free Multi Z and Etherea Internal units.
@dgclimatecontrol Thank you for that information and re...
By Toodles , 9 hours ago
-
RE: My Kronoterm Adapt 0312 ASHP is finally installed!
@editor It was serendipitous really. Both my wife and I...
By tomasmcguinness , 14 hours ago
-
@mrkfm, I'd also suggest that whenever you're ready, st...
By Mars , 1 day ago
-
RE: Are you planning to use a wood burner to supplement your central heating this winter?
I use my stove daily for backup and comfort. Definitely...
By Margarethomas , 1 day ago
-
@rob-of-york Thanks. I wish I'd started on this site as...
By mrkfm , 1 day ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@downfield I just checked this morning and OE just r...
By Papahuhu , 1 day ago
-
RE: Passiv Smart Thermostat - Help & Forum Support
Thanks Will. I'll probably be a week or so before get...
By Singlespeed , 2 days ago
-
RE: Cooling using an air to water heat pump
From experience this summer, a single-split A2A unit on...
By Rob of York , 2 days ago
-
Analysis of the economics of switching to an A2W ASHP compared to other heat sources
This post aims to analyse the economics of installing, ...
By Rob of York , 3 days ago
-
RE: Cooling with air to water heat pumps
@editor does that mean you have to have two separate ex...
By mrkfm , 4 days ago