Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

AgentGeorge
@agentgeorge
Member
Estimable Member
Joined: Feb 11, 2025
Last seen: Apr 15, 2026
Topics: 3 / Replies: 164
Reply
RE: Battery disconnected

@toodles anyone who is afraid of a couple of test tickles

6 months ago
Reply
RE: Battery disconnected

Need to put a warming on this thread incase anyone is following it… If it’s a discharged pp3 you'll get a tizzy tongue, don't try it with a fresh one....

6 months ago
Reply
RE: Battery disconnected

@transparent there is big difference in LV vs HV for DC circuits compared AC. A 9v PP3 battery will kill you if you are daft enough to put your tong...

6 months ago
Reply
RE: Battery disconnected

My take on it is microphones need mAmps whereas cars need Amps. although both work on 48V, one will give you a buzz, the other will launch you across ...

6 months ago
Reply
RE: Battery disconnected

@transparent yup, the cost no longer has VAT, but installer cost, for 2 people is £300-400, profit for company 50% so battery wholesale cost is arou...

6 months ago
Reply
RE: Battery disconnected

I enquired to my installer to add a second battery. I was told they add it on top of the current battery pack. The second battery has a plate on the b...

6 months ago
Reply
RE: Battery disconnected

The batteries would be in parallel, not series. if one of them had a fault, it would be detected by the charging circuit in the Inverter and shutdow...

6 months ago
Reply
RE: Battery disconnected

I have an 80A main fuse, DNO upgraded me from 60A and unlooped me from another meter head when I applied for EV approval I have 5kW of PV and 5kW of...

6 months ago
Reply
RE: What crazy nonsense are inverter limits and why are they imposed?

If you’re interested in finding out which of your neighbours is on the same colour as you, get a mains driven baby monitor and play music on it, then ...

6 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

@toodles i learnt by not screwing down enough, assuming water now cut off and undoing the radiator, to then get spurted with water; not most fun you c...

6 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

@toodles only if you screw them down tight just dropping them on and half a turn is enough to keep the valve clear of debris and rad hot

6 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

Here is the same day from my HP, I have temp set at 20 at all times, im getting a COP in mud 4s this month. The 1pm spike is the hot water boost, I ...