@bontwoody on my gen6 Samsung it's FSV #4013 Heating Off Temp, and by default is set to OAT of 35C (I have reduced mine to 25C). Like @ashp-bobba says...
I cannot speak for other manufacturers, but I know Samsung's WC 'curves' are very simplistic with just two set points with a straight line between, an...
Not an issue for us as there is no mains gas in our village despite an LNG terminal just down the road and a major 1m diameter gas main for the LNG pa...
Our March generation was 133% of our PVGIS prediction at 400kWh generated versus 300kWh predicted from our south facing 3.645kWp array. Now winter i...
As @bontwoody says, if they are inside the heated envelope of the house then it becomes a question of whether it is more beneficial for more of the he...
Gutted for you. We are waiting to hear on our application to increase our solar array to 7.2kWp and add a Tesla PW3 battery (max 11.04kW export), but ...
General wisdom is to oversize the array slightly, so if your export limit is 5kW (and you have or can add a 5kW inverter), then being able to generate...
We ran our radiations at anywhere between 30-35C over winter. At 30C I struggle to tell they are on. If I place my face over the top of the radiator, ...
No issues here in West Wales, touch wood our supply is very stable. In a situation like that, I'd definitely be looking at a battery solution with ful...
Over-sized 12kW Samsung gen6 ASHP, low mileage, one careful owner seeks 8kW unit for long term relationship.
Interesting. We currently find morning solar is most beneficial for us as we can run the heat pump on solar following an overnight switch off (we ofte...
Octopus recently launched their own very similar scheme called the Collective:
- 23 Forums
- 2,098 Topics
- 46.2 K Posts
- 307 Online
- 3,385 Members
Join Us!
Latest Posts
-
RE: Ecodan consuming 100kwh per day in new build!!!
@anca1808 I have just reviewed the whole thread. In s...
By JamesPa , 1 hour ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 12 hours ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 12 hours ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 19 hours ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 1 day ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 1 day ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 2 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 2 days ago
-
If you are thinking of heating on the immersion conside...
By JamesPa , 3 days ago
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness, I think your best bet would be using ...
By Aventus Eco , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@toodles all depends on asking the right questions! And...
By Tim441 , 4 days ago
-
RE: Commencing on an ASHP Installation Process
I received confirmation this morning that my Greener Ho...
By Sheriff Fatman , 4 days ago
-
@jamespa Thanks for the advice - very helpful. I had al...
By abam48 , 5 days ago