- can you clarify what this mean, please? Did you move into a property with the ASHP already installed (under a previous owner) or did you have the AS...
@derek-m @iancalderbank In the Grant/Chofu docs it's referred to as 'defrost temperature', so that's what Ive labelled it. I'm guessing it's a tempera...
Those valves you show are either open or closed - there's no 'partially open' option. They should be in the 'auto' position (far right) but they have ...
I've noticed three types of Defrost Cycle (or at least their impacts on performance) which are all nicely shown in today's data. Overnight it was...
Last Sunday, it was average -1.3C and very damp, so was in "defrost hell" which is every 40ish mins for a Grant: yesterday, it was +1.3C and dry, ...
There's also a parameter (41 22 I think) which controls how long the system pump runs after the compressor is off. I don't think this can run to hours...
@dannymoss23 Yes - Constant Curve is Constant Speed (constant speed is a poor name, but you can see why it is that). Proportional Pressure is NOT reco...
Hi - two things I've found reduced the 'flow noise' I was getting, might help you too: 1. Check for trapped air in your system i.e. bleed rads, and ...
43 13 = "Backup heater set point during Frost protection" which I guess means that if you have a backup heater, that's when it will start to help with...
I'm close enough to the pump to hear it running, but the compressor isn't on, just the pump. And it ties in with the outdoor temp being between 3C and...
I've just checked on my controller and Frost Protection symbol isn't on, even though Frost Protection is running. The explanation of all of the symbol...
This is part of the Grant's 'frost protection' system (as opposed to the 'defrost cycle' which we're all familiar with in this type of weather!), whic...
- 26 Forums
- 2,396 Topics
- 54.3 K Posts
- 319 Online
- 6,077 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Predicted Heat Loss & Needs from MCS calcs vs EPC vs actual
I'd be interested in other experiences - if you have th...
By Tim441 , 7 minutes ago
-
RE: Vaillant aroTherm not heating with many faults
@anon67 Sorry I cant help. The only 'lead' you mi...
By JamesPa , 35 minutes ago
-
RE: Heatpunk Floor plan issues
Now I understand why heat geek and others charge for th...
By jamiejones85 , 51 minutes ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
The diagram below is a simplified view of the internals...
By Batpred , 10 hours ago
-
RE: Heat pump not reaching flow temperature
@davec Ive had a look at the screenshots. Lots of th...
By JamesPa , 11 hours ago
-
RE: Considering MLCP (Multi-Layer Composite Pipe) for ASHP
OK, TBH I dont know enough about MLCP to comment with a...
By JamesPa , 14 hours ago
-
RE: Power outages and storms: A surprisingly good DNO experience
Agreed, which is no more nor less than a customer shoul...
By Majordennisbloodnok , 16 hours ago
-
RE: Running from backup generaor in powercut?
@batpred In our case, 3 times each day when the Octopus...
By Toodles , 16 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
Hi @sheriff-fatman Cycling at 5C and below is usuall...
By RobS , 17 hours ago
-
RE: New Fogstar 15.5kWh upright solution
@batpred Here's the latest Fogstar ready built pack....
By Bash , 18 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@mike-patrick yes, even though the current system is ru...
By Tim441 , 18 hours ago
-
RE: Solis inverters S6-EH1P: pros and cons and battery options
Solis confirmed that the S6 works with a single battery...
By Batpred , 19 hours ago
-
RE: Who has a V2G EV installation
I am wondering if in any V2X, would the car battery eve...
By Batpred , 19 hours ago
-
RE: Setback savings - fact or fiction?
Yes, by calculating it manually from the minute data, w...
By cathodeRay , 21 hours ago
-
Fan unit Making terrible noise HELP!!
One of a pair of fan units on an Earth Save Classic II ...
By GutoFfowc , 21 hours ago
-
RE: New Mitsubishi Ecodan 11.2kW installation - L9 errors and maybe more
OK. I think your system, which seems well designed, is...
By JamesPa , 23 hours ago
-
RE: Fan is clipping ice build up from the front of unit.
@majordennisbloodnok I’ll not go there thanks! Toodles.
By Toodles , 2 days ago
-
RE: Running my new Nibe ASHP efficiently
I'm new to the forum. Did you get a reply to this last ...
By Mike @ Camelot , 2 days ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
@grantmethestrength MCS requirements for DHW capacity h...
By Toodles , 2 days ago