Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 20, 2026
Topics: 28 / Replies: 5524
Reply
RE: Heat loss calculators and spread sheets

@lakey Do you have half hourly or daily readings and what was the heating pattern. Basically my ashp was sized on gas meter readings and the fabric s...

2 years ago
Reply
RE: Twin 10kw Grant Aerona Volumiser Tanks using lots of power

Thats the only logical explanation because for their main function they emphatically dont. Could be, then once he had received them he realised t...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

I remember thats where you started (conservatism in heat loss). What do you actually know in total about heat loss. Do you have any consumption fig...

2 years ago
Reply
RE: Fujitsu Waterstage WOYG160LJL Air Source Heat Pump

Once its running at lowest possible FT you might be able to reassess the operating mode when its mild. Depending on your house, when its mild (which ...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

Fair enough. Obviously you understand that you will take a running cost hit but all designs are a trade off. 45 is often a good compromise for radia...

2 years ago
Reply
RE: Twin 10kw Grant Aerona Volumiser Tanks using lots of power

I still am not sure you get the point of volumiser tanks. They add water volume to the system. They don't need power. Grant and others take the op...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

Are you saying your design flow temperature (at the lowest oat) for the ashp system is 55C? Fans on fancoils do run constantly, but with a decent...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

I'm sorry but I don't understand your maths. If you need 2.4-3kW output then you will need a radiator rated for about 6kW at 50C DT. That's a very bi...

2 years ago
Reply
RE: Fujitsu Waterstage WOYG160LJL Air Source Heat Pump

I think that's very likely. Thus if you set all external controls to be permanently on you should be able to optimise the wc curve to the lowest poss...

2 years ago
Reply
RE: Twin 10kw Grant Aerona Volumiser Tanks using lots of power

Please post back on how you get on. You need to give some thought to those ufh loops, they can't be allowed to suck energy out during dhw cycle. Re...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

They will run without a fan but output is then less than a radiator of same size. I thought you were struggling to fit a passive radiator in hence w...

2 years ago
Reply
RE: Heat loss calculators and spread sheets

Could a fan coil be suitable. I had a similar problem which was solved with a fan coil.

2 years ago