Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 18, 2026
Topics: 27 / Replies: 5258
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

To the final question yes. If the HP is delivering 43 and through to rads its 37, then you are losing about 12-20% in efficiency as a result of the...

2 years ago
Reply
RE: Just one room not reaching desired temperature

If the rads are sized correctly then I would normally say that it could (most probably, but not certainly, is) be an emitter balancing issue. However...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

OK, the most interesting thing is the temperature drop across the buffer measured between flow from HP and flow to radiators. I dont think I can see ...

2 years ago
Reply
RE: 4 port buffer tank connections

With a very low loss house running at very low flow temperatures its true that the reduction in efficiency from running at the only slightly higher fl...

2 years ago
Reply
RE: 4 port buffer tank connections

FWIW my boiler did the same. Sometimes I heard it coming on at 3am in the morning. It heated as well during these forced 'on' periods. But yes, if...

2 years ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

Yuk (comment on the LLH) In this case surely the secondary must be kept running during defrost, otherwise the only water volume available for defros...

2 years ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Good luck on the modbus. I think you are in with a good chance, these units are based on aircon units used in commercial settings where modbus will l...

2 years ago
Reply
RE: Roughly confirming ASHP sizing using existing heat data

... and the value for air changes. Judging by posts on this forum and elsewhere, and comments from a handful of some more independently thinking ins...

2 years ago
Reply
RE: 4 port buffer tank connections

Probably not a lot unless you have UFH, although there is a risk of condensation on the pipes When ASHPs are used for cooling one problem that occur...

2 years ago
Reply
RE: Mitsubishi Ecodan 8.5kW Monobloc (FTC5) Defrost Mode

That seems reasonable if you have a good sized buffer tank between primary and secondary. but not if you have a plate heat exchanger or low loss heade...

2 years ago
Reply
RE: 4 port buffer tank connections

I suspect the experience differs a lot from heat pump to heat pump and house to house. When my 7kW Vaillant (no buffer tank or volumiser) defrosts th...

2 years ago
Reply
RE: Roughly confirming ASHP sizing using existing heat data

As you say you have to make assumptions about boiler efficiency, probably best based on boiler age and whether it actually condenses or not. Cooking...

2 years ago