Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Oct 19, 2026
Topics: 28 / Replies: 5520
Reply
RE: Performance of Heat Pumps in Mild Weather

@heatgeek I feel this may all be heading towards a conclusion that there are a set of trade offs in compressor modulation range and cycling. Without ...

2 years ago
Reply
RE: Performance of Heat Pumps in Mild Weather

Thanks for that. The ecoforest graph of cop Vs compressor speed explains a lot. Perhaps it even explains how Daikin appear to do a single compressor...

2 years ago
Reply
RE: Performance of Heat Pumps in Mild Weather

1.8kW is at 7C, the more interesting figure I think is the min at say 12-15C. That doesn't appear to be specified for the Hitachi, but for the heat p...

2 years ago
Reply
RE: Performance of Heat Pumps in Mild Weather

@heatgeek @robs I was going to say exactly what @robs has said. The interesting metric is the ratio between min output at high OAT/low FT and max ou...

2 years ago
Reply
RE: Help me keep the faith with my air source heat pump installation

2 port buffer/volumiser is fine, will help with defrost/system volume and no downsides. 2 ports good, 4 ports bad! The general rule for rads is to ...

2 years ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

The full sentence was "larger radiators = lower flow temperature and larger system volume. The latter certainly would be expected to reduce cycling...

2 years ago
Reply
RE: Performance of Heat Pumps in Mild Weather

Thank you for pointing that out, I should have commented on this also (but as you say there is a lot here). I did note this comment, am not disputing...

2 years ago
Reply
RE: Performance of Heat Pumps in Mild Weather

Further to the above I discovered a bit more/had an additional thought about Daikin compressors. Firstly Daikin do make their own compressors so its ...

2 years ago
Reply
RE: Newbie: utterly confused with my Mitsubishi Zubadan air source heat pump running on 55C set flow temperature

I must say Im also coming to the conclusion that there is a problem of this nature. OP has optimised the initially high flow temperature and its now ...

2 years ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

Very much agree. I think OP is over-concerned about this because, as you say, cycling is 'designed in'. Also very much agree We may be spli...

2 years ago
Reply
RE: Performance of Heat Pumps in Mild Weather

'and thus its capacity' assumes that output is a linear function of modulation frequency. But I dont think thats the key point so lets not argue over ...

2 years ago
Reply
RE: Ecodan - is there actually such a thing as a 'minimum' flow temp to avoid cycling, and why if so?

Aren't you potentially confusing two things here. OP could of course increase rad size/ volume and reduce ft but that won't change the minimum output...

2 years ago
Page 273 / 463
Share:

SPONSORS

Join Us!

Installer Finder

Degrees of Separation

Latest Posts

SPONSORS

Click to access the login or register cheese
Protected By
Shield Security PRO