Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Derek M
@derek-m
Member
Illustrious Member
Joined: Mar 4, 2021
Last seen: Sep 19, 2024
Topics: 7 / Replies: 4403
Reply
RE: YouTube Presentation worth Looking At

He is obviously a good salesman, but some of his technical knowledge is a little suspect. I welcome any ideas and methods that help ensure heat pump ...

3 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

I can't remember ever having used an IR thermometer, but then I've always had access to what I would term correct test equipment. I do believe that on...

3 years ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Even if there is no itemised section titled commissioning, I would suggest applying a deduction to the overall bill, since the system was not left fun...

3 years ago
Reply
RE: Problems with Daikin 18 kW High Temp ASHP

I suppose that this is a good reason to avoid HT heat pumps if at all possible. To produce a higher LWT the compressor has to work harder, therefore ...

3 years ago
Reply
RE: Avoid the Heat Pump Villain: Why Low-Loss Headers and Buffers Can Sabotage Your Heat Pump's Efficiency

If you have any more heretical thoughts then please let me know, so that I can send the Inquisitor round. 😋 The loss isn't actual thermal e...

3 years ago
Reply
RE: Problems with Daikin 18 kW High Temp ASHP

@haggistrap Is it documented that this is a 12kW heat pump with a 6kW booster heater, rather than a true 18kW heat pump? If so then I would suspect ...

3 years ago
Reply
RE: Problems with Daikin 18 kW High Temp ASHP

@haggistrap Having a 6kW booster heater operating may help reduce the load on the heat pump, and hence reduce the need for defrost cycles, but I su...

3 years ago
Reply
RE: Grant Aerona3 10kw - Few questions

Just to add to the advice given by MikeFl. The objective is to match the Weather Compensation (WC) curve as closely as possible to the heat loss of...

3 years ago
Reply
RE: New ASHP system - choices

Buffer tanks, LLH's and PHE's were required in systems using gas or oil boilers, where radiators would be fitted with TRV's, or in zoned systems where...

3 years ago
Reply
RE: Heat pump efficiency v Outside Air Temperature

To all Forum members and others. Could I please ask any forum members or guest who have received advice to spend a little time and report back upon ...

3 years ago