Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Sep 19, 2024
@markc Mark, One thing that you could try would be to tap the valve body with a rubber mallet or a block of wood, which may free the valve if it ...
@markc Hi Mark, It would appear that the valve is the problem, here is a video you may find of interest./p> I don't think that it will be possi...
@markc Mark, Move the lever to the valve open position and then let go, it should return to the closed position via spring action. If this is not...
@markc Hi Mark, I think that you are correct that the DHW valve is not functioning correctly, this is shown by the changes in operation after you...
Hi Dan, From what I have read in the operator's manual, it would appear that you cannot use the weather compensation facility if you have a thermost...
Dan, The Therma V does support weather compensation. How familiar are you with the operation of your controller and how is your system controlled at...
@markc Mark, Looking at the photo it looks like your controller is an FTC5, can you please confirm. Because your controller is located in your ut...
Hi Dan, Weather compensation is a capability that most modern ASHP's appear to have. If you provide the manufacturer and model details I will check ...
@markc I am assuming by your comments that your system has not been set up for weather compensation. Whilst I have a read through the Ecodan manual...
Hi Mark, You were obviously speaking with the head of the technical help department!!!!! There is a formula for the calculation of SCOP, which inv...
Hi Porthy, I was actually going to suggest that you get the installer back and ensure that they resolve all the issues to your satisfaction before y...
- 27 Forums
- 2,746 Topics
- 64.6 K Posts
- 1,089 Online
- 7,152 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis, I’ve followed this thread pretty much from the...
By Mars , 31 minutes ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
First time poster here but I can share my experience as...
By SCH , 6 hours ago
-
At the risk of going on: A slight side issue for a foru...
By Bart , 12 hours ago
-
RE: Is it the house or the equipment?
...which, I've found out, is pretty much impossible to ...
By Majordennisbloodnok , 14 hours ago
-
RE: Mitsubishi Ecodan FTC6 settings
The Mitsi remote thermostat should not be plugged into ...
By F1p , 1 day ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@lizzie Thank you, very interesting and useful informat...
By Toodles , 1 day ago
-
RE: PV and battery long payback - sense check query
@jamespa I was just commenting on the speed, not sug...
By Batpred , 1 day ago
-
Readers here please note that Derril Water and many oth...
By Transparent , 1 day ago
-
RE: Advice on Vaillant Sensocomfort
Oops, I meant Sensocomfort (the UI to the controls)
By Batpred , 2 days ago
-
RE: Heat Pump Training vs. Real-World Installation
Our instal was very much the opposite. White haired blo...
By Batpred , 2 days ago
-
RE: Flushing system, cleaning and inhibitor
While skim reading a manual for our Vaillant HW tank, I...
By Batpred , 2 days ago
-
RE: 'Chinese Diesel Heater' to heat the home .....
Old thread but I'm new to the forum so new to me. How...
By BlizzardGreen , 2 days ago
-
I'm not sure why you would want to make it more difficu...
By JamesPa , 2 days ago