Dropped into to a newly opened Energy Support Hub run by volunteers this morning to see what they had to offer. There was already someone in there bem...
@gunboatdiplomat A little more complicated. I have one small room that is entirely solid wall, one large room with one wall run that is about 15% soli...
@jamespa I agree it's sensible - now I know what their strategy is and it's not just a huge error. As I posted earlier they will be offering a much la...
A final ‘No’ from Octopus. Apparently they accept that I might have a heat loss of 10w but their software is not able to distinguish the subtleties be...
@gunboatdiplomat That’s good news and a good price as well - I’m only faintly jealous. My indicative quote came out at £6200 (including an unvented ho...
@ivanopinion Octopus have told me they will have a Cosy 16 next year capable of delivering 50c and will cover the alleged 14kw heat loss - if I’d like...
@jamespa I’ve challenged Octopus’s figures using the very helpful comments from this forum. They’ve come back and admitted that the heat loss might no...
@jamespa - great idea. I’ll download the data. @gunboatdiplomat - yes similar house. Mine is detached, 160sqmtr, 300mm plus insulation, double glaz...
@ivanopinion and @jamespa. I do have the half hour readings (but then so do Octopus). However I’m going to have one last go. Today I called a local fi...
@jamespa My actual gas usage is 16500kwh & electricity 3500kwh. My survey assumed a heat demand of 19200kwh. So a heat loss of 14300w? It can’t be...
@jamespa That’s a really interesting article. I’m a hostage to fortune with Octopus as computer says No. I don’t believe my house heat loss is as they...
There is certainly something different about the Octopus process. My Octopus survey, as I’ve mentioned elsewhere, suggested a heat loss of 14300w and ...
- 21 Forums
- 1,960 Topics
- 42.5 K Posts
- 46 Online
- 2,275 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
Volumisers in Heat Pump Systems: Does Placement Matter?
The debate over buffer tanks in heat pump systems has b...
By Mars , 10 minutes ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
@johnr An extra rad was installed in the lounge when th...
By BAMi , 12 minutes ago
-
RE: SolarPV tables / online calculator
By Gary , 45 minutes ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
Yes, that sounds correct. I would say try both options...
By Old_Scientist , 10 hours ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 11 hours ago
-
RE: Setback savings - fact or fiction?
The great thing about science is that it doesn't care o...
By JamesPa , 12 hours ago
-
RE: Act now to defer the UK road tax increase on EVs
@majordennisbloodnok Damn right sir. my attempt at iron...
By Jancold , 14 hours ago
-
RE: ASHP and heating issues in new build house
That’s good gives you more capacity. It made me think, ...
By Terry1812 , 15 hours ago
-
RE: Seewet manhole cover within r290 exclusion zone
Thanks! I asked Vaillant, and they say I should be fi...
By dbrb2 , 18 hours ago
-
Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
I'm running my Aerona 3 on WC and the 'warm end of that...
By damonc , 19 hours ago
-
RE: Do I just go with the lowest quote for my heat pump?
So after signing in Sept in two weeks the install may s...
By Jancold , 20 hours ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
When you are renovating is always a good time, as it ma...
By JamesPa , 23 hours ago
-
RE: Just one room not reaching desired temperature
Looks like this issue is now resolved. Aira installed a...
By ChandyKris , 24 hours ago
-
There have been several people on the OpenEnergyMonitor...
By RobS , 2 days ago
-
RE: Say hello and introduce yourself
Good point @jamespa But that probably strengthens @ch...
By Transparent , 2 days ago
-
RE: Towel rails. An unexpected final hurdle
@jamespa Beware; the use of the term ‘WC’ might lead to...
By Toodles , 2 days ago
-
RE: Visit a Heat Pump sessions.
Congratulations @toodles, that's a fantastic result. We...
By Old_Scientist , 2 days ago
-
RE: Baxi Air Source Heat Pump tips and tricks please
@cathyem1 - thanks for the update. Let us know how it g...
By cathodeRay , 2 days ago
-
RE: Low COP and unevenly heated rooms with 12kW Samsung AE120MXTPEH / AE260TNWTEH
@editor But do you wear your peaked cap the right way r...
By Toodles , 2 days ago
Latest Topics
-
Volumisers in Heat Pump Systems: Does Placement Matter?
By Mars 10 minutes ago
-
SolarPV tables / online calculator
By MichelleC 7 hours ago
-
Samsung Gen 7 R290 12kW is not behaving how I expected
By Joshua 19 hours ago
-
Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
By BAMi 22 hours ago
-
By Toodles 2 days ago
-
Solid manhole cover within r290 exclusion zone
By dbrb2 2 days ago
-
Towel rails. An unexpected final hurdle
By Davesoa 2 days ago