Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 15, 2026
Yes, here's a.mix of Bluetooth and modbus based ones. @transparent @bash It seems the Solis is providing a moving average of power, making it see...
@majordennisbloodnok For my money no advice can be taken.. I do feel the status is as usual favouring professionals. But is the enthusiasm of the wi...
I really have no idea
I know this is a bit old, but it made me wonder what could have led to the use of PACE in 16kwh batteries, then replaced by Seplos (with JK balancers)...
Mine has a Seplos BMS, but I do not see the charging slowing. When it reaches 100 soc, it stops. Perhaps the slowing only works with some specific BMS...
My kit had a Seplos v3 BMS and a JK load balancer. Do you mean you replaced both with the JK drift pro?
@bash My DNO had already issued me with the MPAN. So while the Octopus process was not a "no win no fee" type of process, it was a calculated risk. ...
Thanks, does that leverage anything from your inverter and not available on the Solis? I am wondering if tuning the JK balancer that Fogstar include...
My graph shows a straight red line when charging to 100%, so it is not doing that:
@transparent I thought it is clear enough and helpful to @jancold and others. I saw the limitations of the timed discharge periods, they are actual...
You can press the test button. I posted a bit more about it above. In our case, we could use MCBs.. We may look at it again if we find a detail...
Yes, it was a very reasonable payment. Less than 10% of the £3200 the full MCS service would have costed us (of course not directly comparable)! ...
- 26 Forums
- 2,677 Topics
- 62.6 K Posts
- 487 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump installation quotations
That will be absolutely murdering your energy efficienc...
By EtchedPixels , 6 hours ago
-
RE: Harvest Thermal - ASHP with a smart thermal battery
The cooling side works much better if you can figure ou...
By EtchedPixels , 7 hours ago
-
Floor standing brackets for K3 rads
My neighbour is a plumber and said I would need to fit ...
By Singlespeed , 7 hours ago
-
After an intense recode, I’m pleased to announce that w...
By Mars , 7 hours ago
-
Why do you want to maintain a specific deltaT? The out...
By JamesPa , 9 hours ago
-
Hopefully this will answer your question. To...
By ASHP-BOBBA , 9 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I would be interested to find out if others do this and...
By ASHP-BOBBA , 10 hours ago
-
Don't you dare. You just carry on as you are; as @batpr...
By Majordennisbloodnok , 11 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@ragtime27 some rooms in our house only have one place ...
By Judith , 11 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 15 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 16 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 16 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 20 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 2 days ago