Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

swwils
@swwils
Member
Estimable Member
Joined: Oct 2, 2025
Last seen: Jul 22, 2026
Topics: 0 / Replies: 97
Reply
RE: Battery with existing PV - regulations

@batpred The EPS output can be tricky to do to current regs. The old "rcd socket for type 2 only!" doesn't really cut it anymore.

9 months ago
Reply
RE: A2A vs A2W: Which Heat Pump Would You Pick?

A2A is really good. Simple. Cheap. Great success in other countries. Use it 80% of the year then kick on your alternative source. Even a single casset...

9 months ago
Reply
RE: Battery with existing PV - regulations

G99 needed for ac coupled battery. DNO will assume it can export unless it is type tested G100 and installed how the DNO likes to be export proof. Lim...

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamespa/p> Run starts at 11. It didn't do a defrost the blip in the middle is me canceling a HW call.

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamespa it seems to run at max 27L/min until 45C and then ramps down to 14L/min at 60C then stays there at 60C 14L/min. I was absolutely cooking so...

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

I set the cosy 9 to 70C fixed flow today and let it have at it.   Super interesting, when it reached 60C flow it began widening dT instead of...

9 months ago
Reply
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@andrewj Certainly mine cycles alot below 36C, it seems "happier" with the weather compensated minimum flow temperature at 36ºC or above. I think the ...

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

It definitely doesn't have a regular weather curve control algorithm. Unless you "force" it too by setting a room target very high.

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamespa the insides are very well done. High quality compressor and inverter. Such a large monolithic case is also an achievement in itself. Pe...

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@jamespa I would guess it's a deliberate choice due the compressor selection, it's minimum stable compression ratio is probably close when at 34C. A...

9 months ago
Reply
RE: Octopus Cosy Heat Pump Owners & Discussion Thread

@agentgeorge ESP32 since its what I had in the drawer

9 months ago