Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jun 2, 2026
@jamespa/p> Run starts at 11. It didn't do a defrost the blip in the middle is me canceling a HW call.
@jamespa it seems to run at max 27L/min until 45C and then ramps down to 14L/min at 60C then stays there at 60C 14L/min. I was absolutely cooking so...
I set the cosy 9 to 70C fixed flow today and let it have at it. Super interesting, when it reached 60C flow it began widening dT instead of...
@agentgeorge mine does switch back
@andrewj Certainly mine cycles alot below 36C, it seems "happier" with the weather compensated minimum flow temperature at 36ºC or above. I think the ...
It definitely doesn't have a regular weather curve control algorithm. Unless you "force" it too by setting a room target very high.
@jamespa the insides are very well done. High quality compressor and inverter. Such a large monolithic case is also an achievement in itself. Pe...
@jamespa I would guess it's a deliberate choice due the compressor selection, it's minimum stable compression ratio is probably close when at 34C. A...
@agentgeorge ESP32 since its what I had in the drawer
@batpred I think you probably got the wrong end of the stick with this supplier. Maybe stick to givenergy?
My fogstar seplos battery has been great and the service fantastic. I don't run an active balancer but did match and top-balance the cells. I wrote a ...
I was asked if I was happy before I was even issued the certificate in a handover pack.
- 26 Forums
- 2,677 Topics
- 62.6 K Posts
- 196 Online
- 7,090 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Heat pump installation quotations
That will be absolutely murdering your energy efficienc...
By EtchedPixels , 3 hours ago
-
RE: Harvest Thermal - ASHP with a smart thermal battery
The cooling side works much better if you can figure ou...
By EtchedPixels , 3 hours ago
-
Floor standing brackets for K3 rads
My neighbour is a plumber and said I would need to fit ...
By Singlespeed , 4 hours ago
-
After an intense recode, I’m pleased to announce that w...
By Mars , 4 hours ago
-
Why do you want to maintain a specific deltaT? The out...
By JamesPa , 6 hours ago
-
Hopefully this will answer your question. To...
By ASHP-BOBBA , 6 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I would be interested to find out if others do this and...
By ASHP-BOBBA , 6 hours ago
-
Don't you dare. You just carry on as you are; as @batpr...
By Majordennisbloodnok , 8 hours ago
-
RE: Heat pump design review please: 5 kW Vaillant aroTHERM Plus heat pump
@ragtime27 some rooms in our house only have one place ...
By Judith , 8 hours ago
-
RE: Several AC coupled batteries
That is a good point, a manufacturers can stop trading,...
By Batpred , 12 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Hi @hanno - good question. The range of hybrid invert...
By Transparent , 12 hours ago
-
RE: GivEnergy inverter tripping due to over-voltage?
@transparent the inverter was installed in 2021 and afa...
By Tim441 , 13 hours ago
-
RE: Say hello and introduce yourself
I hope so, @toodles. It's not often that we see a situa...
By Majordennisbloodnok , 16 hours ago
-
RE: Electricity price predictions
Good point, I do expect the bonus of putting my energy ...
By Batpred , 2 days ago