Reply
RE: Grant Aerona3 13kW Noisy pipes after balancing

Regarding noise, we run at fixed flow rates of between 24-26L/min (so similar to you), and have a new system with 22mm copper runs, branching off to 1...

3 weeks ago
Reply
RE: Solar for heating DHW

Similar situation here, although slightly lower numbers as I have a 12kW ASHP and a 3kW solar inverter. In the summer*, I try to limit the power dra...

1 month ago
Reply
RE: Heat Pump starting current

I have seen mentioned two things that may help alleviate the effects of defrost cycles. The first is having sufficiently large thermal mass within t...

1 month ago
Reply
RE: Investment or not Solar/Battery instllation

I'm not sure I follow. I have a 12kW Samsung ASHP, and starting from cold, which we do most mornings as we often switch off overnight, the system norm...

1 month ago
Reply
RE: My 2.5kW array is only putting out 1kWh in an entire day

I generated 6.4kWh on Saturday 2.8kWh on Sunday and 7.4kWh yesterday from my south facing 3.65kWp array - Saturday and yesterday were very good days w...

1 month ago
Reply
RE: Samsung ASHP owners what have you set your weather compensation to?

I'm running a 'flat' WL curve of 32C (32C @ 15C OAT; 32C @ -2C OAT), and I then manually adjust LWT up and down on the controller heating screen. At t...

1 month ago
Reply
RE: Samsung weather compensation oddities

I don't know how having two zones may complicate/affect things, especially as presumably the two zones may require different flow temps? With #2091-...

4 months ago
Reply
RE: Samsung weather compensation oddities

@cloudclear sounds like a good plan. I do not have any monitoring, so am simply collecting data and recording through studious observations. FSV #20...

4 months ago
Reply
RE: Samsung weather compensation oddities

I believe the guys above have nailed it. I have a similar 12kW Gen6 Samsung and observe exactly the same. The heat that the ASHP is producing has to...

4 months ago
Reply
RE: Determining correct flow rate?

That would be the more logical place to fit them, but ours is installed on the main return pipe back to the heat pump, so affects both DHW and heating...

6 months ago
Reply
RE: Determining correct flow rate?

@rhh2348 My system has a 50L volumiser fitted in the main 28mm return pipework, which at the end of the DWH cycle will also contain 50L of hot (55C) w...

6 months ago
Page 5 / 10
Share:

Join Us!

Heat Pump Dramas?

Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.

Pre-Installation Planning
Post-Installation Troubleshooting
Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)

👉 Book a one-to-one consultation now.

Latest Posts

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security