Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

NetDonkey
@netdonkey
Member
Trusted Member
Joined: Sep 10, 2024
Last seen: Jan 31, 2025
Topics: 2 / Replies: 54
Reply
RE: Samsung E911 intermittent issue

@transparent Noted re the lagging and yes the arrow is the flow sensor. Have reseated this cable too just incase

1 year ago
Reply
RE: Samsung E911 intermittent issue

@ashp-bobba It trips on both but more frequently with DHW. Re the flow rate when ion DHW, I think its the same FSV but will have a look

1 year ago
Reply
RE: Samsung E911 intermittent issue

@ashp-bobba pics attached. Flow direction indicator in it points upwards

1 year ago
Reply
RE: Samsung E911 intermittent issue

@ashp-bobba reasonably confident to have a look at it. The current system pressure is 1.7bar which from googling seems ok.

1 year ago
Reply
RE: Samsung E911 intermittent issue

@toodles worth giving that an inspection?

1 year ago
Reply
RE: Samsung E911 intermittent issue

@editor Can't see anything that resembles a Y filter. There does seem to be a big black fillter (pic attached) which might be a filter? Before...

1 year ago
Reply
RE: Samsung E911 intermittent issue

A new symptom this morning. The HP shut off overnight with the E911 error. I have reset everything as usual and now the HP isn't coming on but the...

1 year ago
Reply
RE: Samsung E911 intermittent issue

@editor will have a look for it tomorrow. How hard is it to open and clean? I assume there will be a stop valve/cut off either side of it?

1 year ago
Reply
RE: Samsung E911 intermittent issue

@ashp-bobba 28mm I believe but will get the tape measure out tomorrow.

1 year ago
Reply
RE: Samsung E911 intermittent issue

@ashp-bobba Thanks. The pipework run from the ASHP to main plant is around 13m. Would the strainer be near the pump or the main plant? I assume the ...

1 year ago
Topic
Replies: 110
Views: 18994
Reply
RE: Say hello and introduce yourself

@transparent I will be asking the same question about why it was situated in the loft rather than outside. Will let you know what they say.

2 years ago