Reply
RE: Is the Grant controller a thermostat?

I'd echo what @allyfish said. I too have a 10kW Grant, and about 150m2 to heat. During the cold snap I was consuming 50-60kWh per day, and this didn't...

2 years ago
Reply
RE: Heat pumps don't work: debunking myths & misconceptions

@editor I think it's important to focus on "energy used" rather than COP. HP owners tend to focus on COP, which is quite a novel concept for non-HP pe...

2 years ago
Reply
RE: Delta T with a Low Loss Header

I've been bending my brain trying to balance my LLH (Grant install one by default these days it seems - I suspect to ease the installer's job from wha...

2 years ago
Reply
RE: Is the Grant controller a thermostat?

@sentinam Yes. Parameter '21 04'; the temperature at which the HP will be aiming at the high LWT value set in parameter '21 02'. By 'High LWT' I meant...

2 years ago
Reply
RE: Is the Grant controller a thermostat?

@mab I think most have changed their low end to 0 from -4, I have. I guess once you're at zero, you'll need 'high LWT'. I'm getting the figures from...

2 years ago
Reply
RE: Grant ASHP not reaching target temperatures

Hopefully things have improved now the cold snap has reached its end ... ? There are many (too many) parameters to consider to improve performance, ...

2 years ago
Reply
RE: Is the Grant controller a thermostat?

@mab As it's been seconds since any graphs were posted, here are two interesting ones from over the weekend, both showing a couple of defrost periods....

2 years ago
Reply
RE: Our Grant Aerona R32 13kW ASHP installation

@marvinator80 Who are you getting to service? Do you have a local engineer, or are you going to Grant via their "annual service plan"?

2 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

@jamespa This is what Grant recommend (insist?) on. There's no "if you fancy it" it's "this is how we want it done" for all Grant installs. Grant do...

2 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

@marvinator80 No, these are parameters beginning '46' (see the linked document in my first post). Your LLH needs to have the immersion heater element ...

2 years ago
Reply
RE: Any Grant Aerona owners using their Low Loss Header immersion heater?

@jamespa Grant describe it as a "combined low loss header and volumiser". This bit of kit comes with all standard Grant installs, and has the flow/ret...

2 years ago